Application and Description | These cables are suitable for domestic premises, kitchen, office for light service or light portable apparatuses. With tdeir special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoided. |
Standard and Approval | HD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295 CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1 |
Cable Construction | - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T13 to VDE-0281 Part 1 - Color coded to VDE-0293-308 - PVC outer jacket TM3 |
Technical Characteristics | - Working voltage: 300/300 volts - Test voltage: 3000 volts - Flexing bending radius: 15 x Ø - Static bending radius: 4 x Ø - Flexing temperature: +5º C to +90º C - Static temperature: -40º C to +90º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km |
Cable Parameter
AWG | NO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM² | NOMINAL THICKNESS OF INSULATIONMM | NOMINAL THICKNESS OF SHEATHMM | NOMINAL OVERALL DIAMETERMM | NOMINAL COPPER WEIGHTKG/KM | NOMINAL WEIGHTKG/KM |
H03V2V2-F | ||||||
20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 5 | 9.6 | 38 |
20(16/32) | 3 x 0.50 | 0.5 | 0.6 | 5.4 | 14.4 | 45 |
20(16/32) | 4 x 0.50 | 0.5 | 0.6 | 5.8 | 19.2 | 55 |
18(24/32) | 2 x 0.75 | 0.5 | 0.6 | 5.5 | 14.4 | 46 |
18(24/32) | 3 x 0.75 | 0.5 | 0.6 | 6 | 21.6 | 59 |
18(24/32) | 4 x 0.75 | 0.5 | 0.6 | 6.5 | 28.8 | 72 |
H03V2V2H2-F | ||||||
20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 3.2 x 5.2 | 9.7 | 32 |
18(24/32) | 2 x 0.75 | 0.5 | 0.3 | 3.4 x 5.6 | 14.4 | 35 |
Application and Description | These cables are suitable for domestic premises, kitchen, office for light service or light portable apparatuses. With tdeir special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperatures (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoided. |
Standard and Approval | HD 21.12; HD 308 S2 DIN VDE 0281 part 1, part 12; DIN VDE 0293 part 308; DIN VDE 0295 CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), EN50265-2-1 |
Cable Construction | - Bare copper fine wire conductor - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383 - PVC core insulation T13 to VDE-0281 Part 1 - Color coded to VDE-0293-308 - PVC outer jacket TM3 |
Technical Characteristics | - Working voltage: 300/300 volts - Test voltage: 3000 volts - Flexing bending radius: 15 x Ø - Static bending radius: 4 x Ø - Flexing temperature: +5º C to +90º C - Static temperature: -40º C to +90º C - Short circuit temperature: +160º C - Flame retardant: IEC 60332.1 - Insulation resistance: 20 MΩ x km |
Cable Parameter
AWG | NO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM² | NOMINAL THICKNESS OF INSULATIONMM | NOMINAL THICKNESS OF SHEATHMM | NOMINAL OVERALL DIAMETERMM | NOMINAL COPPER WEIGHTKG/KM | NOMINAL WEIGHTKG/KM |
H03V2V2-F | ||||||
20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 5 | 9.6 | 38 |
20(16/32) | 3 x 0.50 | 0.5 | 0.6 | 5.4 | 14.4 | 45 |
20(16/32) | 4 x 0.50 | 0.5 | 0.6 | 5.8 | 19.2 | 55 |
18(24/32) | 2 x 0.75 | 0.5 | 0.6 | 5.5 | 14.4 | 46 |
18(24/32) | 3 x 0.75 | 0.5 | 0.6 | 6 | 21.6 | 59 |
18(24/32) | 4 x 0.75 | 0.5 | 0.6 | 6.5 | 28.8 | 72 |
H03V2V2H2-F | ||||||
20(16/32) | 2 x 0.50 | 0.5 | 0.6 | 3.2 x 5.2 | 9.7 | 32 |
18(24/32) | 2 x 0.75 | 0.5 | 0.3 | 3.4 x 5.6 | 14.4 | 35 |