Applications | These cables are designed for connections between units of mine distribution systems, suitable fordirect burial in wet and dry locations. |
Standards | ICEA S-75-381/NEMA WC 58 ASTM B-8 CAN/CSA-C22.2 No.96 |
Construction | |
Conductors | Stranded annealed bare copper conductor. |
Conductor Shield | Conducting layer. |
Insulation | Cross-Linked Polyethylene (XLPE). |
Insulation Shield | Conducting layer + copper tape. |
Ground Check Conductor | Copper conductor with a yellow polypropylene insulation. |
Grounding Conductor | Tinned copper conductor. |
Jacket | Polyvinyl Chloride (PVC), black. |
Options | Other jacket materials such as CSP/PCP/NBR/PVC are available upon request. Two-layer jacket with reinforcing fibre between the two layers can be offered as an option. |
Mechanical and Thermal Properties | Minimum Bending Radius: 12×OD Maximum Operating Temperature: +90℃ |
Dimensions and Weight:
Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Jacket Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | ||||
No. of cores×AWG/kcmil | - | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
3×4 | 7 | 8 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.41 | 35.8 | 1224 | 1821 | 122 |
3×2 | 7 | 6 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.47 | 37.3 | 1653 | 2459 | 159 |
3×1 | 19 | 5 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.54 | 39.1 | 1950 | 2901 | 184 |
3×1/0 | 19 | 4 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.63 | 41.4 | 2200 | 3273 | 211 |
3×2/0 | 19 | 3 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.72 | 43.7 | 2721 | 4048 | 243 |
3×3/0 | 19 | 2 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 1.89 | 48.0 | 3170 | 4720 | 279 |
3×4/0 | 19 | 1 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.01 | 51.0 | 3845 | 5721 | 321 |
3×250 | 37 | 1/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.10 | 53.3 | 4321 | 6429 | 355 |
3×350 | 37 | 2/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.31 | 58.7 | 5652 | 8409 | 435 |
3×500 | 37 | 4/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.59 | 65.8 | 7721 | 11487 | 536 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Applications | These cables are designed for connections between units of mine distribution systems, suitable fordirect burial in wet and dry locations. |
Standards | ICEA S-75-381/NEMA WC 58 ASTM B-8 CAN/CSA-C22.2 No.96 |
Construction | |
Conductors | Stranded annealed bare copper conductor. |
Conductor Shield | Conducting layer. |
Insulation | Cross-Linked Polyethylene (XLPE). |
Insulation Shield | Conducting layer + copper tape. |
Ground Check Conductor | Copper conductor with a yellow polypropylene insulation. |
Grounding Conductor | Tinned copper conductor. |
Jacket | Polyvinyl Chloride (PVC), black. |
Options | Other jacket materials such as CSP/PCP/NBR/PVC are available upon request. Two-layer jacket with reinforcing fibre between the two layers can be offered as an option. |
Mechanical and Thermal Properties | Minimum Bending Radius: 12×OD Maximum Operating Temperature: +90℃ |
Dimensions and Weight:
Construction | No. of Strands | Grounding Conductor Size | Ground Check Conductor Size | Nominal Insulation Thickness | Nominal Jacket Thickness | Nominal Overall Diameter | Nominal Weight | Ampacity | ||||
No. of cores×AWG/kcmil | - | AWG/kcmil | AWG/kcmil | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
3×4 | 7 | 8 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.41 | 35.8 | 1224 | 1821 | 122 |
3×2 | 7 | 6 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.47 | 37.3 | 1653 | 2459 | 159 |
3×1 | 19 | 5 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.54 | 39.1 | 1950 | 2901 | 184 |
3×1/0 | 19 | 4 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.63 | 41.4 | 2200 | 3273 | 211 |
3×2/0 | 19 | 3 | 8 | 0.09 | 2.3 | 0.11 | 2.8 | 1.72 | 43.7 | 2721 | 4048 | 243 |
3×3/0 | 19 | 2 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 1.89 | 48.0 | 3170 | 4720 | 279 |
3×4/0 | 19 | 1 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.01 | 51.0 | 3845 | 5721 | 321 |
3×250 | 37 | 1/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.10 | 53.3 | 4321 | 6429 | 355 |
3×350 | 37 | 2/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.31 | 58.7 | 5652 | 8409 | 435 |
3×500 | 37 | 4/0 | 8 | 0.09 | 2.3 | 0.14 | 3.6 | 2.59 | 65.8 | 7721 | 11487 | 536 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.