Availability: | |
---|---|
Quantity: | |
Application | The cables are designed to give good protection to the core against inductive interference (RF=0.3).The cables are used for outdoor signaling equipment. |
Standards | RENFE E.T. 03.365.051.6 |
Construction | |
Conductors: | Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228 |
Insulation: | Solid polyethylene as per ASTM D 1248/IEC 60708 |
Cabling Element: | Four insulated conductors are twisted together to form a quad |
Cable Core Assembly: | The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders |
Core Wrapping: | One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap |
Electrostatic Screen: | Corrugated copper tape of 0.12mm is applied longitudinally with overlap |
Bedding: | PE or LSZH |
Electrostatic Armour: | Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one |
Sheath: | PE, PVC or LSZH |
Ripcord: | Nylon ripcord may be placed parallel to the cores to facilitate sheath removal |
Electrical Properties
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
Conductor Size | mm2 | 0.636 | 1.539 |
Maximum Conductor Resistance @20°C | Ω/km | 28 | 12.1 |
Minimum Insulation Resistance @500V DC | MΩ.km | 35000 | 5000 |
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km | 0.3 | 0.3 | |
Induced Voltage Em 500V/Km | 0.5 | 0.5 | |
Maximum Resistance Unbalance | % | 2.5 | 2.5 |
Maximum Mutual Capacitance @0.8Hz | nF/km | 45 | 50 |
Maximum Capacitance Unbalance @1KHz pair-to-pair | pF/500m | 250 | 250 |
Maximum Capacitance Unbalance @1KHz pair-to-ground | pF/500m | 1200 | 1200 |
Maximum Average Attenuation @1KHz | dB/km | 0.7 | 0.46 |
Maximum Average Attenuation @10KHz | dB/km | 1.6 | 0.85 |
Maximum Average Attenuation @30KHz | dB/km | 2.1 | 1.3 |
Dielectric Strength Conductor to Conductor 3secs | V DC | 3000 | 3000 |
Conductor to Screen 3secs | V DC | 3500 | 3500 |
Nominal Insulation Thickness | mm | 0.45 | 0.65 |
Nominal Insulated Conductor Diameter | mm | 1.8 | 2.7 |
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Colour Code
Layer | Quad Position | Colour of conductors | |||
1 | 2 | 3 | 4 | ||
Centre and even layers | First | ORANGE | GREEN | RED | WHITE |
Even | YELLOW | GREEN | BLUE | WHITE | |
Odd | YELLOW | GREEN | RED | WHITE | |
Last | ORANGE | GREEN | BLUE | WHITE | |
Odd Layers | First | ORANGE | GREEN | RED | BLACK |
Even | YELLOW | GREEN | BLUE | BLACK | |
Odd | YELLOW | GREEN | RED | BLACK | |
Last | ORANGE | GREEN | BLUE | BLACK |
Dimensions And Weight
Cable Code | Number of Quads | Nominal Bedding/Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
0.9mm Conductor, 1.8mm Insulated Wire | ||||
UE-TP365-2Y(CTS)2Y(DSTA)Y1Q09-RF03 | 1 | 1.5/1.6 | 18.3 | 1300 |
UE-TP365-2Y(CTS)2Y(DSTA)Y3Q09-RF03 | 3 | 1.5/1.6 | 21.7 | 1425 |
UE-TP365-2Y(CTS)2Y(DSTA)Y5Q09-RF03 | 5 | 1.5/1.6 | 25.2 | 1650 |
UE-TP365-2Y(CTS)2Y(DSTA)Y7Q09-RF03 | 7 | 1.5/1.6 | 26.7 | 1800 |
UE-TP365-2Y(CTS)2Y(DSTA)Y10Q09-RF03 | 10 | 1.5/1.6 | 29.2 | 2275 |
UE-TP365-2Y(CTS)2Y(DSTA)Y14Q09-RF03 | 14 | 1.6/1.8 | 32.3 | 2450 |
UE-TP365-2Y(CTS)2Y(DSTA)Y19Q09-RF03 | 19 | 1.7/1.8 | 36.0 | 2895 |
UE-TP365-2Y(CTS)2Y(DSTA)Y27Q09-RF03 | 27 | 1.7/1.8 | 40.5 | 3275 |
UE-TP365-2Y(CTS)2Y(DSTA)Y37Q09-RF03 | 37 | 1.8/2.0 | 45.6 | 3775 |
UE-TP365-2Y(CTS)2Y(DSTA)Y48Q09-RF03 | 48 | 1.9/2.0 | 49.8 | 4275 |
1.4mm Conductor, 2.7mm Insulated Wire | ||||
UE-TP365-2Y(CTS)2Y(DSTA)Y1Q14-RF03 | 1 | 1.5/1.6 | 20.2 | 1615 |
UE-TP365-2Y(CTS)2Y(DSTA)Y3Q14-RF03 | 3 | 1.5/1.6 | 25.7 | 1775 |
UE-TP365-2Y(CTS)2Y(DSTA)Y5Q14-RF03 | 5 | 1.6/1.8 | 30.8 | 2200 |
UE-TP365-2Y(CTS)2Y(DSTA)Y7Q14-RF03 | 7 | 1.6/1.8 | 32.8 | 2525 |
UE-TP365-2Y(CTS)2Y(DSTA)Y10Q14-RF03 | 10 | 1.7/1.8 | 36.5 | 2975 |
UE-TP365-2Y(CTS)2Y(DSTA)Y14Q14-RF03 | 14 | 1.7/1.8 | 40.5 | 3150 |
UE-TP365-2Y(CTS)2Y(DSTA)Y19Q14-RF03 | 19 | 1.8/2.0 | 45.6 | 3695 |
UE-TP365-2Y(CTS)2Y(DSTA)Y27Q14-RF03 | 27 | 2.0/2.2 | 52.3 | 3975 |
UE-TP365-2Y(CTS)2Y(DSTA)Y37Q14-RF03 | 37 | 2.1/2.2 | 59.1 | 4475 |
UE-TP365-2Y(CTS)2Y(DSTA)Y48Q14-RF03 | 48 | 2.2/2.3 | 66.0 | 4975 |
Application | The cables are designed to give good protection to the core against inductive interference (RF=0.3).The cables are used for outdoor signaling equipment. |
Standards | RENFE E.T. 03.365.051.6 |
Construction | |
Conductors: | Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228 |
Insulation: | Solid polyethylene as per ASTM D 1248/IEC 60708 |
Cabling Element: | Four insulated conductors are twisted together to form a quad |
Cable Core Assembly: | The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders |
Core Wrapping: | One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap |
Electrostatic Screen: | Corrugated copper tape of 0.12mm is applied longitudinally with overlap |
Bedding: | PE or LSZH |
Electrostatic Armour: | Two steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one |
Sheath: | PE, PVC or LSZH |
Ripcord: | Nylon ripcord may be placed parallel to the cores to facilitate sheath removal |
Electrical Properties
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
Conductor Size | mm2 | 0.636 | 1.539 |
Maximum Conductor Resistance @20°C | Ω/km | 28 | 12.1 |
Minimum Insulation Resistance @500V DC | MΩ.km | 35000 | 5000 |
Reduction Factor Rk (50Hz) Induced Voltage Em 100V/Km | 0.3 | 0.3 | |
Induced Voltage Em 500V/Km | 0.5 | 0.5 | |
Maximum Resistance Unbalance | % | 2.5 | 2.5 |
Maximum Mutual Capacitance @0.8Hz | nF/km | 45 | 50 |
Maximum Capacitance Unbalance @1KHz pair-to-pair | pF/500m | 250 | 250 |
Maximum Capacitance Unbalance @1KHz pair-to-ground | pF/500m | 1200 | 1200 |
Maximum Average Attenuation @1KHz | dB/km | 0.7 | 0.46 |
Maximum Average Attenuation @10KHz | dB/km | 1.6 | 0.85 |
Maximum Average Attenuation @30KHz | dB/km | 2.1 | 1.3 |
Dielectric Strength Conductor to Conductor 3secs | V DC | 3000 | 3000 |
Conductor to Screen 3secs | V DC | 3500 | 3500 |
Nominal Insulation Thickness | mm | 0.45 | 0.65 |
Nominal Insulated Conductor Diameter | mm | 1.8 | 2.7 |
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Colour Code
Layer | Quad Position | Colour of conductors | |||
1 | 2 | 3 | 4 | ||
Centre and even layers | First | ORANGE | GREEN | RED | WHITE |
Even | YELLOW | GREEN | BLUE | WHITE | |
Odd | YELLOW | GREEN | RED | WHITE | |
Last | ORANGE | GREEN | BLUE | WHITE | |
Odd Layers | First | ORANGE | GREEN | RED | BLACK |
Even | YELLOW | GREEN | BLUE | BLACK | |
Odd | YELLOW | GREEN | RED | BLACK | |
Last | ORANGE | GREEN | BLUE | BLACK |
Dimensions And Weight
Cable Code | Number of Quads | Nominal Bedding/Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
0.9mm Conductor, 1.8mm Insulated Wire | ||||
UE-TP365-2Y(CTS)2Y(DSTA)Y1Q09-RF03 | 1 | 1.5/1.6 | 18.3 | 1300 |
UE-TP365-2Y(CTS)2Y(DSTA)Y3Q09-RF03 | 3 | 1.5/1.6 | 21.7 | 1425 |
UE-TP365-2Y(CTS)2Y(DSTA)Y5Q09-RF03 | 5 | 1.5/1.6 | 25.2 | 1650 |
UE-TP365-2Y(CTS)2Y(DSTA)Y7Q09-RF03 | 7 | 1.5/1.6 | 26.7 | 1800 |
UE-TP365-2Y(CTS)2Y(DSTA)Y10Q09-RF03 | 10 | 1.5/1.6 | 29.2 | 2275 |
UE-TP365-2Y(CTS)2Y(DSTA)Y14Q09-RF03 | 14 | 1.6/1.8 | 32.3 | 2450 |
UE-TP365-2Y(CTS)2Y(DSTA)Y19Q09-RF03 | 19 | 1.7/1.8 | 36.0 | 2895 |
UE-TP365-2Y(CTS)2Y(DSTA)Y27Q09-RF03 | 27 | 1.7/1.8 | 40.5 | 3275 |
UE-TP365-2Y(CTS)2Y(DSTA)Y37Q09-RF03 | 37 | 1.8/2.0 | 45.6 | 3775 |
UE-TP365-2Y(CTS)2Y(DSTA)Y48Q09-RF03 | 48 | 1.9/2.0 | 49.8 | 4275 |
1.4mm Conductor, 2.7mm Insulated Wire | ||||
UE-TP365-2Y(CTS)2Y(DSTA)Y1Q14-RF03 | 1 | 1.5/1.6 | 20.2 | 1615 |
UE-TP365-2Y(CTS)2Y(DSTA)Y3Q14-RF03 | 3 | 1.5/1.6 | 25.7 | 1775 |
UE-TP365-2Y(CTS)2Y(DSTA)Y5Q14-RF03 | 5 | 1.6/1.8 | 30.8 | 2200 |
UE-TP365-2Y(CTS)2Y(DSTA)Y7Q14-RF03 | 7 | 1.6/1.8 | 32.8 | 2525 |
UE-TP365-2Y(CTS)2Y(DSTA)Y10Q14-RF03 | 10 | 1.7/1.8 | 36.5 | 2975 |
UE-TP365-2Y(CTS)2Y(DSTA)Y14Q14-RF03 | 14 | 1.7/1.8 | 40.5 | 3150 |
UE-TP365-2Y(CTS)2Y(DSTA)Y19Q14-RF03 | 19 | 1.8/2.0 | 45.6 | 3695 |
UE-TP365-2Y(CTS)2Y(DSTA)Y27Q14-RF03 | 27 | 2.0/2.2 | 52.3 | 3975 |
UE-TP365-2Y(CTS)2Y(DSTA)Y37Q14-RF03 | 37 | 2.1/2.2 | 59.1 | 4475 |
UE-TP365-2Y(CTS)2Y(DSTA)Y48Q14-RF03 | 48 | 2.2/2.3 | 66.0 | 4975 |