Availability: | |
---|---|
Quantity: | |
Applications | These cables are used for the connection of mobile electrical equipment inunderground mines, e.g. for coal-cutting machines,especially for the use in bretby chains with extremebending loads under low tensile stress. |
Standards | VDE 0250 Part 813 |
Construction | |
Conductors | Flexible stranded tinned copper conductor. |
Insulation | Heatresistant3GI3 rubber based on EPR. |
Outer Conductor Layer (for 3.6/6kV) | Easy strippable outer conductive layer. |
Pilot Cores | Copper/steel conductor capable ofexpansion and compression with EPR rubber insulation. |
Earth Conductor | Spiral of tinnedcopper wires and a conductive tape. |
InnerSheath | 2 layer design, semi conductive rubber + Rubber type 5GM5. |
Armour | Spiral of steel wires,embedded in the outer sheath, fiberglas tape which preventssheath exchanging. |
Outer Sheath | Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant. |
Dimensions and Weight
1.8/3 (3.6) kV
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×35+3×(1.5ST+25/3)+UEL | 44.0 | 49.0 | 3900 |
3×50+3×(1.5ST+25/3)+UEL | 50.0 | 55.0 | 5100 |
3×70+3×(1.5ST+35/3)+UEL | 52.0 | 56.0 | 6200 |
3×95+3×(1.5ST+50/3)+UEL | 58.0 | 62.0 | 7500 |
3×120+3×(1.5ST+70/3)+UEL | 64.0 | 70.0 | 9350 |
3.6/6 (7.2) kV
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×35+3×(1.5ST+25/3)+UEL | 49.0 | 54.0 | 5800 |
3×50+3×(1.5ST+25/3)+UEL | 56.0 | 61.0 | 6100 |
3×70+3×(1.5ST+35/3)+UEL | 57.0 | 62.0 | 6700 |
3×95+3×(1.5ST+50/3)+UEL | 62.0 | 66.0 | 8000 |
3×120+3×(1.5ST+70/3)+UEL | 67.0 | 71.0 | 10200 |
Applications | These cables are used for the connection of mobile electrical equipment inunderground mines, e.g. for coal-cutting machines,especially for the use in bretby chains with extremebending loads under low tensile stress. |
Standards | VDE 0250 Part 813 |
Construction | |
Conductors | Flexible stranded tinned copper conductor. |
Insulation | Heatresistant3GI3 rubber based on EPR. |
Outer Conductor Layer (for 3.6/6kV) | Easy strippable outer conductive layer. |
Pilot Cores | Copper/steel conductor capable ofexpansion and compression with EPR rubber insulation. |
Earth Conductor | Spiral of tinnedcopper wires and a conductive tape. |
InnerSheath | 2 layer design, semi conductive rubber + Rubber type 5GM5. |
Armour | Spiral of steel wires,embedded in the outer sheath, fiberglas tape which preventssheath exchanging. |
Outer Sheath | Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant. |
Dimensions and Weight
1.8/3 (3.6) kV
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×35+3×(1.5ST+25/3)+UEL | 44.0 | 49.0 | 3900 |
3×50+3×(1.5ST+25/3)+UEL | 50.0 | 55.0 | 5100 |
3×70+3×(1.5ST+35/3)+UEL | 52.0 | 56.0 | 6200 |
3×95+3×(1.5ST+50/3)+UEL | 58.0 | 62.0 | 7500 |
3×120+3×(1.5ST+70/3)+UEL | 64.0 | 70.0 | 9350 |
3.6/6 (7.2) kV
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×35+3×(1.5ST+25/3)+UEL | 49.0 | 54.0 | 5800 |
3×50+3×(1.5ST+25/3)+UEL | 56.0 | 61.0 | 6100 |
3×70+3×(1.5ST+35/3)+UEL | 57.0 | 62.0 | 6700 |
3×95+3×(1.5ST+50/3)+UEL | 62.0 | 66.0 | 8000 |
3×120+3×(1.5ST+70/3)+UEL | 67.0 | 71.0 | 10200 |