Applications | These cables are used for the connection of mobile machines under extremelyhigh mechanical loads, predominantly in miningsituations,e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress. |
Standards | DIN VDE 0250 Part 812 |
Construction | |
Conductors | Flexible stranded tinned copper conductor. |
Insulation | Heatresistant3GI3 rubber based on EPR. |
Outer Conductor Layer | Easy strippable outer conductive layer. |
Pilot Cores | Copper strand and steelbraid conductor capable ofexpansion and compression with EPRrubber insulation. |
Monitoring Conductor | Spiral of tinned copper wires above the pilot cores, covered with a semi-conductive tape. |
InnerSheath | Rubber type GM1b. |
Armour/Earth Conductor | Concentric earth conductor as spiral of copper and steel wires,fibreglas tape, embedded in the outer sheath whichprevents sheath exchanging. |
Outer Sheath | Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant. |
Dimensions and Weight
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×16/16KON+2ST+UEL | 35.0 | 38.0 | 2130 |
3×25/16KON+2ST+UEL | 38.0 | 41.0 | 2790 |
3×35/16KON+2ST+UEL | 41.0 | 45.0 | 3390 |
3×50/25KON+2ST+UEL | 47.0 | 51.0 | 4340 |
3×70/35KON+2ST+UEL | 52.0 | 56.0 | 5680 |
3×95/50KON+2ST+UEL | 58.0 | 62.0 | 7180 |
3×25/16KON+3×(1.5ST+UEL) | 38.0 | 41.0 | 2920 |
3×35/16KON+3×(1.5ST+UEL) | 41.0 | 45.0 | 3630 |
3×50/25KON+3×(1.5ST+UEL) | 45.0 | 48.0 | 4500 |
3×70/35KON+3×(1.5ST+UEL) | 48.0 | 53.0 | 5850 |
3×95/50KON+3×(1.5ST+UEL) | 52.0 | 56.0 | 7400 |
3×120/70KON+3×(1.5ST+UEL) | 58.0 | 63.0 | 8300 |
3×150/70KON+3×(1.5ST+UEL) | 62.0 | 68.0 | 9300 |
Applications | These cables are used for the connection of mobile machines under extremelyhigh mechanical loads, predominantly in miningsituations,e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress. |
Standards | DIN VDE 0250 Part 812 |
Construction | |
Conductors | Flexible stranded tinned copper conductor. |
Insulation | Heatresistant3GI3 rubber based on EPR. |
Outer Conductor Layer | Easy strippable outer conductive layer. |
Pilot Cores | Copper strand and steelbraid conductor capable ofexpansion and compression with EPRrubber insulation. |
Monitoring Conductor | Spiral of tinned copper wires above the pilot cores, covered with a semi-conductive tape. |
InnerSheath | Rubber type GM1b. |
Armour/Earth Conductor | Concentric earth conductor as spiral of copper and steel wires,fibreglas tape, embedded in the outer sheath whichprevents sheath exchanging. |
Outer Sheath | Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant. |
Dimensions and Weight
Number of Cores×Nominal Cross Section | Minimium Overall Diameter | Maximum Overall Diameter | Nominal Weight |
No.×mm² | mm | mm | kg/km |
3×16/16KON+2ST+UEL | 35.0 | 38.0 | 2130 |
3×25/16KON+2ST+UEL | 38.0 | 41.0 | 2790 |
3×35/16KON+2ST+UEL | 41.0 | 45.0 | 3390 |
3×50/25KON+2ST+UEL | 47.0 | 51.0 | 4340 |
3×70/35KON+2ST+UEL | 52.0 | 56.0 | 5680 |
3×95/50KON+2ST+UEL | 58.0 | 62.0 | 7180 |
3×25/16KON+3×(1.5ST+UEL) | 38.0 | 41.0 | 2920 |
3×35/16KON+3×(1.5ST+UEL) | 41.0 | 45.0 | 3630 |
3×50/25KON+3×(1.5ST+UEL) | 45.0 | 48.0 | 4500 |
3×70/35KON+3×(1.5ST+UEL) | 48.0 | 53.0 | 5850 |
3×95/50KON+3×(1.5ST+UEL) | 52.0 | 56.0 | 7400 |
3×120/70KON+3×(1.5ST+UEL) | 58.0 | 63.0 | 8300 |
3×150/70KON+3×(1.5ST+UEL) | 62.0 | 68.0 | 9300 |