Availability: | |
---|---|
Quantity: | |
Application | These armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke& halogen free, suitable for installations on passenger ships, as on other commercial vessels. |
Standards | IEC 60092-350/351/376/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Class 2 stranded copper conductor. |
Inner Covering | Lapping. |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). SHF2 can be offered upon request. |
Core Identification | White with printed number. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +80℃ |
Dimensions and Weight
Part No. | Construction No. of cores×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
M092-RE-2XCH-2C0.75 | 2×0.75 | 0.5 | 1.2 | 7.2 | 80 |
M092-RE-2XCH-3C0.75 | 3×0.75 | 0.5 | 1.2 | 7.5 | 90 |
M092-RE-2XCH-5C0.75 | 5×0.75 | 0.5 | 1.4 | 8.9 | 130 |
M092-RE-2XCH-7C0.75 | 7×0.75 | 0.5 | 1.6 | 9.8 | 150 |
M092-RE-2XCH-12C0.75 | 12×0.75 | 0.5 | 1.7 | 12.4 | 230 |
M092-RE-2XCH-19C0.75 | 19×0.75 | 0.5 | 1.9 | 14.6 | 320 |
M092-RE-2XCH-27C0.75 | 27×0.75 | 0.5 | 2.1 | 17.3 | 460 |
M092-RE-2XCH-37C0.75 | 37×0.75 | 0.5 | 2.2 | 19.3 | 590 |
M092-RE-2XCH-2C1.0 | 2×1.0 | 0.5 | 1.4 | 7.9 | 90 |
M092-RE-2XCH-3C1.0 | 3×1.0 | 0.5 | 1.4 | 8.3 | 100 |
M092-RE-2XCH-5C1.0 | 5×1.0 | 0.5 | 1.5 | 9.7 | 150 |
M092-RE-2XCH-7C1.0 | 7×1.0 | 0.5 | 1.6 | 10.4 | 180 |
M092-RE-2XCH-12C1.0 | 12×1.0 | 0.5 | 1.8 | 13.2 | 270 |
M092-RE-2XCH-19C1.0 | 19×1.0 | 0.5 | 2.1 | 15.9 | 420 |
M092-RE-2XCH-27C1.0 | 27×1.0 | 0.5 | 2.2 | 18.4 | 560 |
M092-RE-2XCH-37C1.0 | 37×1.0 | 0.5 | 2.4 | 20.7 | 710 |
Application | These armoured cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352. These cables are flame retardant, low smoke& halogen free, suitable for installations on passenger ships, as on other commercial vessels. |
Standards | IEC 60092-350/351/376/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Class 2 stranded copper conductor. |
Inner Covering | Lapping. |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). SHF2 can be offered upon request. |
Core Identification | White with printed number. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +80℃ |
Dimensions and Weight
Part No. | Construction No. of cores×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
M092-RE-2XCH-2C0.75 | 2×0.75 | 0.5 | 1.2 | 7.2 | 80 |
M092-RE-2XCH-3C0.75 | 3×0.75 | 0.5 | 1.2 | 7.5 | 90 |
M092-RE-2XCH-5C0.75 | 5×0.75 | 0.5 | 1.4 | 8.9 | 130 |
M092-RE-2XCH-7C0.75 | 7×0.75 | 0.5 | 1.6 | 9.8 | 150 |
M092-RE-2XCH-12C0.75 | 12×0.75 | 0.5 | 1.7 | 12.4 | 230 |
M092-RE-2XCH-19C0.75 | 19×0.75 | 0.5 | 1.9 | 14.6 | 320 |
M092-RE-2XCH-27C0.75 | 27×0.75 | 0.5 | 2.1 | 17.3 | 460 |
M092-RE-2XCH-37C0.75 | 37×0.75 | 0.5 | 2.2 | 19.3 | 590 |
M092-RE-2XCH-2C1.0 | 2×1.0 | 0.5 | 1.4 | 7.9 | 90 |
M092-RE-2XCH-3C1.0 | 3×1.0 | 0.5 | 1.4 | 8.3 | 100 |
M092-RE-2XCH-5C1.0 | 5×1.0 | 0.5 | 1.5 | 9.7 | 150 |
M092-RE-2XCH-7C1.0 | 7×1.0 | 0.5 | 1.6 | 10.4 | 180 |
M092-RE-2XCH-12C1.0 | 12×1.0 | 0.5 | 1.8 | 13.2 | 270 |
M092-RE-2XCH-19C1.0 | 19×1.0 | 0.5 | 2.1 | 15.9 | 420 |
M092-RE-2XCH-27C1.0 | 27×1.0 | 0.5 | 2.2 | 18.4 | 560 |
M092-RE-2XCH-37C1.0 | 37×1.0 | 0.5 | 2.4 | 20.7 | 710 |