Availability: | |
---|---|
Quantity: | |
Application | These cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. |
Standards | DIN 89159 IEC 60092-351/375/359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Stranded copper conductor. |
Insulation | Mica tape + HEPR. |
Cabling Element | Pair. |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). |
Core Identification | Pair: White/blue with printed pair number and core number. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +75℃ |
Dimensions and Weight
Part No. | Construction No. of elements×No. of cores in element×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
MFR-M3GCH-1P0.75 | 1×2×0.75 | 0.5 | 1.2 | 10.5 | 110 |
MFR-M3GCH-2P0.75 | 2×2×0.75* | 0.5 | 1.3 | 11.0 | 150 |
MFR-M3GCH-4P0.75 | 4×2×0.75 | 0.5 | 1.4 | 16.0 | 270 |
MFR-M3GCH-7P0.75 | 7×2×0.75 | 0.5 | 1.8 | 19.0 | 400 |
MFR-M3GCH-10P0.75 | 10×2×0.75 | 0.5 | 1.9 | 22.0 | 560 |
MFR-M3GCH-14P0.75 | 14×2×0.75 | 0.5 | 2.0 | 27.0 | 740 |
MFR-M3GCH-19P0.75 | 19×2×0.75 | 0.5 | 2.1 | 29.0 | 930 |
MFR-M3GCH-24P0.75 | 24×2×0.75 | 0.5 | 2.2 | 31.0 | 1110 |
*: 2 pairs are assembled as a quad.
Application | These cables are used on board of ships in all locations for fixed installations complying with IEC standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels. |
Standards | DIN 89159 IEC 60092-351/375/359 IEC 60331-21 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Stranded copper conductor. |
Insulation | Mica tape + HEPR. |
Cabling Element | Pair. |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). |
Core Identification | Pair: White/blue with printed pair number and core number. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +75℃ |
Dimensions and Weight
Part No. | Construction No. of elements×No. of cores in element×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
MFR-M3GCH-1P0.75 | 1×2×0.75 | 0.5 | 1.2 | 10.5 | 110 |
MFR-M3GCH-2P0.75 | 2×2×0.75* | 0.5 | 1.3 | 11.0 | 150 |
MFR-M3GCH-4P0.75 | 4×2×0.75 | 0.5 | 1.4 | 16.0 | 270 |
MFR-M3GCH-7P0.75 | 7×2×0.75 | 0.5 | 1.8 | 19.0 | 400 |
MFR-M3GCH-10P0.75 | 10×2×0.75 | 0.5 | 1.9 | 22.0 | 560 |
MFR-M3GCH-14P0.75 | 14×2×0.75 | 0.5 | 2.0 | 27.0 | 740 |
MFR-M3GCH-19P0.75 | 19×2×0.75 | 0.5 | 2.1 | 29.0 | 930 |
MFR-M3GCH-24P0.75 | 24×2×0.75 | 0.5 | 2.2 | 31.0 | 1110 |
*: 2 pairs are assembled as a quad.