Availability: | |
---|---|
Quantity: | |
Application | Theses cables are designed for use witd cathodic systems protecting against galvanic and electrolytic corrosion of metallic objects such as underground pipelines, tanks and otder buried or submerged metallic structures. HMWPE cathodic protection cable utilizes stranded copper conductors that are insulated witd a high molecular weight polyetdylene (HMWPE) compound that provides strong resistance to abrasion, crushing, chemicals, oil, moisture and other elements. |
Standard | ICEA S-95-658 |
Conductor | Soft drawn bare copper stranded to ASTM B3 & B8. |
Insulation | High molecular weight polyetdylene (PE) compound in accordance with the requirements ASTM D1248 for Type 1 Class C Category 4 or 5 Grade E5 material and ICEA S-95-658. |
Technical Data | Rated Voltage: 600V Operating Temperature: 75℃ |
Dimensions
CONDUCTOR SIZE | STRANDING | INSULATION THICKNESS | NOMINAL OUTER DIAMETER | TOTAL WEIGHT |
IN | IN | LBS/MFT | ||
8 AWG | 7/0.486 | 0.11 | 0.370 | 90 |
6 AWG | 7/0.612 | 0.11 | 0.410 | 126 |
4 AWG | 7/0.772 | 0.11 | 0.460 | 182 |
2 AWG | 7/0.974 | 0.125 | 0.520 | 269 |
1 AWG | 19/0.664 | 0.125 | 0.595 | 340 |
1/0 AWG | 19/0.745 | 0.125 | 0.635 | 415 |
2/0 AWG | 19/0.837 | 0.125 | 0.68 | 509 |
3/0 AWG | 19/0.940 | 0.125 | 0.735 | 627 |
4/0 AWG | 19/1.055 | 0.125 | 0.795 | 774 |
250 KCMIL | 37/0.822 | 0.155 | 0.9 | 935 |
350 KCMIL | 37/0.973 | 0.155 | 1.01 | 1271 |
Application | Theses cables are designed for use witd cathodic systems protecting against galvanic and electrolytic corrosion of metallic objects such as underground pipelines, tanks and otder buried or submerged metallic structures. HMWPE cathodic protection cable utilizes stranded copper conductors that are insulated witd a high molecular weight polyetdylene (HMWPE) compound that provides strong resistance to abrasion, crushing, chemicals, oil, moisture and other elements. |
Standard | ICEA S-95-658 |
Conductor | Soft drawn bare copper stranded to ASTM B3 & B8. |
Insulation | High molecular weight polyetdylene (PE) compound in accordance with the requirements ASTM D1248 for Type 1 Class C Category 4 or 5 Grade E5 material and ICEA S-95-658. |
Technical Data | Rated Voltage: 600V Operating Temperature: 75℃ |
Dimensions
CONDUCTOR SIZE | STRANDING | INSULATION THICKNESS | NOMINAL OUTER DIAMETER | TOTAL WEIGHT |
IN | IN | LBS/MFT | ||
8 AWG | 7/0.486 | 0.11 | 0.370 | 90 |
6 AWG | 7/0.612 | 0.11 | 0.410 | 126 |
4 AWG | 7/0.772 | 0.11 | 0.460 | 182 |
2 AWG | 7/0.974 | 0.125 | 0.520 | 269 |
1 AWG | 19/0.664 | 0.125 | 0.595 | 340 |
1/0 AWG | 19/0.745 | 0.125 | 0.635 | 415 |
2/0 AWG | 19/0.837 | 0.125 | 0.68 | 509 |
3/0 AWG | 19/0.940 | 0.125 | 0.735 | 627 |
4/0 AWG | 19/1.055 | 0.125 | 0.795 | 774 |
250 KCMIL | 37/0.822 | 0.155 | 0.9 | 935 |
350 KCMIL | 37/0.973 | 0.155 | 1.01 | 1271 |