Availability: | |
---|---|
Quantity: | |
Application
Suitable for connecting instruments and control systems for analogue or digital signal transmission. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations
Construction
Conductor:
Insulation:
Triple Identification:
Wrapping:
Collective Screen:
Outer Sheath:
Solid, stranded or flexible plain or metal coated copper in accordance with class1, 2 or 5 of HD383 in the range of 0.5mm2 to 1.5mm2.
PE or XLPE to EN 50290. Suitable alternative materials are under consideration.
Black&White&Red color with number on the cores for multi triples, start with 1 in the centre.
At least 1 layer of plastic tape.
Aluminimum foil tape over a tinned copper drain wire.
Halogen free flame retardant compound LSZH, to EN 50290-2-27.
Electrical data at 20°C
Character | Unit | Values | |||||
Conductor size | nom. | mm² | 0.5 | 0.75 | 1.0 | 1.5 | |
Conductor resistance | max. | Ω/km | 36.7 | 25.0 | 18.5 | 12.3 | |
Insulation resistance | min. | MΩ x km | 5000 | ||||
L/R (ratio) | max. | µH/Ω | 25 | 40 | |||
Inductance | max. | mH/km | 1 | ||||
Mutual capacitance | max. | nF/m | 75 | 85 | |||
Capacitance unbalance | max. | pF/500 m | 500 | ||||
Test voltage | V | 1500 | |||||
Operating voltage U0 / U | max. | V | 300 |
Application
Suitable for connecting instruments and control systems for analogue or digital signal transmission. Recommended for indoor and outdoor installation, on racks, trays, in conduits, in dry and wet locations
Construction
Conductor:
Insulation:
Triple Identification:
Wrapping:
Collective Screen:
Outer Sheath:
Solid, stranded or flexible plain or metal coated copper in accordance with class1, 2 or 5 of HD383 in the range of 0.5mm2 to 1.5mm2.
PE or XLPE to EN 50290. Suitable alternative materials are under consideration.
Black&White&Red color with number on the cores for multi triples, start with 1 in the centre.
At least 1 layer of plastic tape.
Aluminimum foil tape over a tinned copper drain wire.
Halogen free flame retardant compound LSZH, to EN 50290-2-27.
Electrical data at 20°C
Character | Unit | Values | |||||
Conductor size | nom. | mm² | 0.5 | 0.75 | 1.0 | 1.5 | |
Conductor resistance | max. | Ω/km | 36.7 | 25.0 | 18.5 | 12.3 | |
Insulation resistance | min. | MΩ x km | 5000 | ||||
L/R (ratio) | max. | µH/Ω | 25 | 40 | |||
Inductance | max. | mH/km | 1 | ||||
Mutual capacitance | max. | nF/m | 75 | 85 | |||
Capacitance unbalance | max. | pF/500 m | 500 | ||||
Test voltage | V | 1500 | |||||
Operating voltage U0 / U | max. | V | 300 |