Availability: | |
---|---|
Quantity: | |
PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V PVC Insulated, Non-sheathed Power Cables (Single Core)
(CU/PVC 600/1000V Class 2)
Application: | The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings. |
STANDARDS: | Basic design adapted to BS 6491X |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test)** | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.
COLOUR CODE
Insulation Colour as per BS7671
With Earth Conductor | Without Earth Conductor | |
2Cores | - | Brown, Blue |
3Cores | Yellow/Green, Brown, Blue | Brown, Gray, Black |
4Cores | Yellow/Green, Brown, Gray, Black | Brown, Gray, Black, Blue |
5Cores | Yellow/Green, Brown, Gray, Black, Blue | Brown, Gray, Black, Blue, Black |
Above 5 Cores | Yellow/Green, Black Numbered | Black Numbered |
Sheath Colour: Black (other colors upon request)
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C
250°C in short-circuit for 5secs max.
Minimum bending radius: 8 x Overall Diameter (unarmoured cable)
10 x Overall Diameter (armoured cable)
CONSTRUCTION PARAMETERS
Conductor | FGD300 1V-R | |||
No. of Core X Cross Section | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Insulated, Non-Sheathed | |
Nominal Overall Diameter | Approx. Weight | |||
Noxmm2 | No./mm | mm | mm | kg/km |
1x1.5 | 7/0.53 | 0.7 | 3.1 | 22 |
1x2.5 | 7/0.67 | 0.8 | 3.7 | 34 |
1x4 | 7/0.85 | 0.8 | 4.3 | 50 |
1x6 | 7/1.04 | 0.8 | 4.8 | 70 |
1x10 | 7/1.35 | 1.0 | 6.2 | 116 |
1x16 | 7/1.70 | 1.0 | 7.2 | 174 |
1x25 | 7/2.14 | 1.2 | 9.0 | 276 |
1x35 | 7/2.52 | 1.2 | 10.0 | 366 |
1x50 | 19/1.78 | 1.4 | 11.9 | 502 |
1x70 | 19/2.14 | 1.4 | 13.7 | 706 |
1x95 | 19/2.52 | 1.6 | 16.0 | 974 |
1x120 | 37/2.03 | 1.6 | 17.6 | 1213 |
1x150 | 37/2.25 | 1.8 | 19.6 | 1492 |
1x185 | 37/2.52 | 2.0 | 21.8 | 1868 |
1x240 | 61/2.25 | 2.2 | 24.4 | 2443 |
1x300 | 61/2.52 | 2.4 | 27.7 | 3055 |
1x400 | 61/2.85 | 2.6 | 31.1 | 3888 |
1x500 | 61/3.20 | 2.8 | 34.6 | 4880 |
1x630 | 127/2.52 | 2.8 | 38.6 | 6229 |
Electrical Properties
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor cross- sectional area | Reference Method 4 (enclosed in conduit in thermally insulating wall etc) | Reference Method 3 (enclosed in conduit on a wall or in trunking etc) | Reference Method 1 (clipped direct) | Reference Method 11 (on a perforated cable tray, horizontal or vertical) | Reference Method 12 (free air) | ||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | |||||||||
2 cables, single- phase a.c. or d.c. | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c. flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or 3 c ables three phase | 2 cables, single- phase a.c. or d.c. or 3 cables three phase | 3 cables, trefoil 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm2 | A | A | A | A | A | A | A | A | A | A | A |
1.5 | 18 | 17 | 22 | 19 | 25 | 23 | - | - | - | - | - |
2.5 | 24 | 23 | 30 | 26 | 34 | 31 | - | - | - | - | - |
4 | 33 | 30 | 40 | 35 | 46 | 41 | - | - | - | - | - |
6 | 43 | 39 | 51 | 45 | 59 | 54 | - | - | - | - | - |
10 | 58 | 53 | 71 | 63 | 81 | 74 | - | - | - | - | - |
16 | 76 | 70 | 95 | 85 | 109 | 99 | - | - | - | - | - |
25 | 100 | 91 | 126 | 111 | 143 | 130 | 158 | 140 | 183 | 163 | 138 |
35 | 125 | 111 | 156 | 138 | 176 | 161 | 195 | 176 | 226 | 203 | 171 |
50 | 149 | 135 | 189 | 168 | 228 | 209 | 293 | 215 | 274 | 246 | 209 |
70 | 189 | 170 | 240 | 214 | 293 | 268 | 308 | 279 | 351 | 318 | 270 |
95 | 228 | 205 | 290 | 259 | 355 | 326 | 375 | 341 | 426 | 389 | 330 |
120 | 263 | 235 | 336 | 299 | 413 | 379 | 436 | 398 | 495 | 453 | 385 |
150 | 300 | 270 | 375 | 328 | 476 | 436 | 505 | 461 | 570 | 524 | 445 |
185 | 341 | 306 | 426 | 370 | 545 | 500 | 579 | 530 | 651 | 600 | 511 |
240 | 400 | 358 | 500 | 433 | 644 | 590 | 686 | 630 | 769 | 711 | 606 |
300 | 459 | 410 | 573 | 493 | 743 | 681 | 794 | 730 | 886 | 824 | 701 |
400 | - | - | 684 | 584 | 868 | 793 | 915 | 849 | 1065 | 994 | 820 |
500 | - | - | 783 | 666 | 990 | 904 | 1044 | 973 | 1228 | 1150 | 936 |
630 | - | - | 900 | 764 | 1130 | 1033 | 1191 | 1115 | 1423 | 1338 | 1069 |
Voltage Drop (Per Amp Per Meter)
Size of conductor | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | |||||||||||||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1 and 11 (clipped direct or on trays touching) | Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1, 11 and 12 (in trefoil) | Ref. Methods 1 and 11 (Flat and touching) | ||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | ||||||||||
mm2 | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||||||||
1.5 | 31 | 31 | 27 | 27 | 27 | 27 | ||||||||||
2.5 | 19 | 19 | 16 | 16 | 16 | 16 | ||||||||||
4 | 33 | 12 | 10 | 10 | 10 | 10 | ||||||||||
6 | 7.8 | 7.9 | 6.8 | 6.8 | 6.8 | 6.8 | ||||||||||
10 | 4.7 | 4.7 | 4.7 | 4 | 4 | 4 | ||||||||||
16 | 2.9 | 2.9 | 2.9 | 2.5 | 2.5 | 2.5 | ||||||||||
r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
25 | 1.85 | 1.85 | 0.31 | 1.90 | 1.85 | 0.190 | 1.85 | 1.60 | 0.27 | 1.65 | 1.600 | 0.165 | 1.600 | 1.600 | 0.190 | 1.600 |
35 | 1.35 | 1.35 | 0.29 | 1.35 | 1.35 | 0.180 | 1.35 | 1.15 | 0.25 | 1.15 | 1.150 | 0.155 | 1.50 | 1.150 | 0.180 | 1.150 |
50 | 0.99 | 1.00 | 0.29 | 1.05 | 0.99 | 0.180 | 1.00 | 0.87 | 0.25 | 0.90 | 0.860 | 0.155 | 0.870 | 0.860 | 0.180 | 0.870 |
70 | 0.68 | 0.70 | 0.28 | 0.75 | 0.68 | 0.175 | 0.71 | 0.60 | 0.24 | 0.65 | 0.590 | 0.150 | 0.610 | 0.590 | 0.175 | 0.620 |
95 | 0.49 | 0.51 | 0.27 | 0.58 | 0.49 | 0.170 | 0.52 | 0.44 | 0.23 | 0.50 | 0.430 | 0.145 | 0.450 | 0.430 | 0.170 | 0.460 |
120 | 0.39 | 0.41 | 0.26 | 0.48 | 0.39 | 0.165 | 0.43 | 0.35 | 0.23 | 0.42 | 0.340 | 0.140 | 0.370 | 0.340 | 0.165 | 0.380 |
150 | 0.32 | 0.33 | 0.26 | 0.43 | 0.32 | 0.165 | 0.36 | 0.29 | 0.23 | 0.37 | 0.280 | 0.140 | 0.310 | 0.280 | 0.165 | 0.320 |
185 | 0.25 | 0.27 | 0.26 | 0.37 | 0.26 | 0.165 | 0.30 | 0.23 | 0.23 | 0.32 | 0.220 | 0.140 | 0.260 | 0.220 | 0.165 | 0.280 |
240 | 0.19 | 0.21 | 0.26 | 0.33 | 0.20 | 0.160 | 0.25 | 0.185 | 0.22 | 0.29 | 0.170 | 0.140 | 0.220 | 0.170 | 0.165 | 0.240 |
300 | 0.155 | 0.175 | 0.25 | 0.31 | 0.16 | 0.160 | 0.22 | 0.150 | 0.22 | 0.27 | 0.140 | 0.140 | 0.195 | 0.135 | 0.160 | 0.210 |
400 | 0.12 | 0.140 | 0.25 | 0.29 | 0.13 | 0.155 | 0.20 | 0.125 | 0.22 | 0.25 | 0.110 | 0.135 | 0.175 | 0.110 | 0.160 | 0.195 |
500 | 0.093 | 0.120 | 0.25 | 0.28 | 0.105 | 0.155 | 0.185 | 0.100 | 0.22 | 0.24 | 0.090 | 0.135 | 0.160 | 0.088 | 0.160 | 0.180 |
630 | 0.072 | 0.100 | 0.25 | 0.27 | 0.086 | 0.155 | 0.175 | 0.088 | 0.21 | 0.23 | 0.074 | 0.135 | 0.150 | 0.071 | 0.160 | 0.170 |
PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V PVC Insulated, Non-sheathed Power Cables (Single Core)
(CU/PVC 600/1000V Class 2)
Application: | The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings. |
STANDARDS: | Basic design adapted to BS 6491X |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test)** | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.
COLOUR CODE
Insulation Colour as per BS7671
With Earth Conductor | Without Earth Conductor | |
2Cores | - | Brown, Blue |
3Cores | Yellow/Green, Brown, Blue | Brown, Gray, Black |
4Cores | Yellow/Green, Brown, Gray, Black | Brown, Gray, Black, Blue |
5Cores | Yellow/Green, Brown, Gray, Black, Blue | Brown, Gray, Black, Blue, Black |
Above 5 Cores | Yellow/Green, Black Numbered | Black Numbered |
Sheath Colour: Black (other colors upon request)
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C
250°C in short-circuit for 5secs max.
Minimum bending radius: 8 x Overall Diameter (unarmoured cable)
10 x Overall Diameter (armoured cable)
CONSTRUCTION PARAMETERS
Conductor | FGD300 1V-R | |||
No. of Core X Cross Section | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Insulated, Non-Sheathed | |
Nominal Overall Diameter | Approx. Weight | |||
Noxmm2 | No./mm | mm | mm | kg/km |
1x1.5 | 7/0.53 | 0.7 | 3.1 | 22 |
1x2.5 | 7/0.67 | 0.8 | 3.7 | 34 |
1x4 | 7/0.85 | 0.8 | 4.3 | 50 |
1x6 | 7/1.04 | 0.8 | 4.8 | 70 |
1x10 | 7/1.35 | 1.0 | 6.2 | 116 |
1x16 | 7/1.70 | 1.0 | 7.2 | 174 |
1x25 | 7/2.14 | 1.2 | 9.0 | 276 |
1x35 | 7/2.52 | 1.2 | 10.0 | 366 |
1x50 | 19/1.78 | 1.4 | 11.9 | 502 |
1x70 | 19/2.14 | 1.4 | 13.7 | 706 |
1x95 | 19/2.52 | 1.6 | 16.0 | 974 |
1x120 | 37/2.03 | 1.6 | 17.6 | 1213 |
1x150 | 37/2.25 | 1.8 | 19.6 | 1492 |
1x185 | 37/2.52 | 2.0 | 21.8 | 1868 |
1x240 | 61/2.25 | 2.2 | 24.4 | 2443 |
1x300 | 61/2.52 | 2.4 | 27.7 | 3055 |
1x400 | 61/2.85 | 2.6 | 31.1 | 3888 |
1x500 | 61/3.20 | 2.8 | 34.6 | 4880 |
1x630 | 127/2.52 | 2.8 | 38.6 | 6229 |
Electrical Properties
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor cross- sectional area | Reference Method 4 (enclosed in conduit in thermally insulating wall etc) | Reference Method 3 (enclosed in conduit on a wall or in trunking etc) | Reference Method 1 (clipped direct) | Reference Method 11 (on a perforated cable tray, horizontal or vertical) | Reference Method 12 (free air) | ||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | |||||||||
2 cables, single- phase a.c. or d.c. | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c. flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or 3 c ables three phase | 2 cables, single- phase a.c. or d.c. or 3 cables three phase | 3 cables, trefoil 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm2 | A | A | A | A | A | A | A | A | A | A | A |
1.5 | 18 | 17 | 22 | 19 | 25 | 23 | - | - | - | - | - |
2.5 | 24 | 23 | 30 | 26 | 34 | 31 | - | - | - | - | - |
4 | 33 | 30 | 40 | 35 | 46 | 41 | - | - | - | - | - |
6 | 43 | 39 | 51 | 45 | 59 | 54 | - | - | - | - | - |
10 | 58 | 53 | 71 | 63 | 81 | 74 | - | - | - | - | - |
16 | 76 | 70 | 95 | 85 | 109 | 99 | - | - | - | - | - |
25 | 100 | 91 | 126 | 111 | 143 | 130 | 158 | 140 | 183 | 163 | 138 |
35 | 125 | 111 | 156 | 138 | 176 | 161 | 195 | 176 | 226 | 203 | 171 |
50 | 149 | 135 | 189 | 168 | 228 | 209 | 293 | 215 | 274 | 246 | 209 |
70 | 189 | 170 | 240 | 214 | 293 | 268 | 308 | 279 | 351 | 318 | 270 |
95 | 228 | 205 | 290 | 259 | 355 | 326 | 375 | 341 | 426 | 389 | 330 |
120 | 263 | 235 | 336 | 299 | 413 | 379 | 436 | 398 | 495 | 453 | 385 |
150 | 300 | 270 | 375 | 328 | 476 | 436 | 505 | 461 | 570 | 524 | 445 |
185 | 341 | 306 | 426 | 370 | 545 | 500 | 579 | 530 | 651 | 600 | 511 |
240 | 400 | 358 | 500 | 433 | 644 | 590 | 686 | 630 | 769 | 711 | 606 |
300 | 459 | 410 | 573 | 493 | 743 | 681 | 794 | 730 | 886 | 824 | 701 |
400 | - | - | 684 | 584 | 868 | 793 | 915 | 849 | 1065 | 994 | 820 |
500 | - | - | 783 | 666 | 990 | 904 | 1044 | 973 | 1228 | 1150 | 936 |
630 | - | - | 900 | 764 | 1130 | 1033 | 1191 | 1115 | 1423 | 1338 | 1069 |
Voltage Drop (Per Amp Per Meter)
Size of conductor | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | |||||||||||||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1 and 11 (clipped direct or on trays touching) | Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1, 11 and 12 (in trefoil) | Ref. Methods 1 and 11 (Flat and touching) | ||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | ||||||||||
mm2 | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||||||||
1.5 | 31 | 31 | 27 | 27 | 27 | 27 | ||||||||||
2.5 | 19 | 19 | 16 | 16 | 16 | 16 | ||||||||||
4 | 33 | 12 | 10 | 10 | 10 | 10 | ||||||||||
6 | 7.8 | 7.9 | 6.8 | 6.8 | 6.8 | 6.8 | ||||||||||
10 | 4.7 | 4.7 | 4.7 | 4 | 4 | 4 | ||||||||||
16 | 2.9 | 2.9 | 2.9 | 2.5 | 2.5 | 2.5 | ||||||||||
r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
25 | 1.85 | 1.85 | 0.31 | 1.90 | 1.85 | 0.190 | 1.85 | 1.60 | 0.27 | 1.65 | 1.600 | 0.165 | 1.600 | 1.600 | 0.190 | 1.600 |
35 | 1.35 | 1.35 | 0.29 | 1.35 | 1.35 | 0.180 | 1.35 | 1.15 | 0.25 | 1.15 | 1.150 | 0.155 | 1.50 | 1.150 | 0.180 | 1.150 |
50 | 0.99 | 1.00 | 0.29 | 1.05 | 0.99 | 0.180 | 1.00 | 0.87 | 0.25 | 0.90 | 0.860 | 0.155 | 0.870 | 0.860 | 0.180 | 0.870 |
70 | 0.68 | 0.70 | 0.28 | 0.75 | 0.68 | 0.175 | 0.71 | 0.60 | 0.24 | 0.65 | 0.590 | 0.150 | 0.610 | 0.590 | 0.175 | 0.620 |
95 | 0.49 | 0.51 | 0.27 | 0.58 | 0.49 | 0.170 | 0.52 | 0.44 | 0.23 | 0.50 | 0.430 | 0.145 | 0.450 | 0.430 | 0.170 | 0.460 |
120 | 0.39 | 0.41 | 0.26 | 0.48 | 0.39 | 0.165 | 0.43 | 0.35 | 0.23 | 0.42 | 0.340 | 0.140 | 0.370 | 0.340 | 0.165 | 0.380 |
150 | 0.32 | 0.33 | 0.26 | 0.43 | 0.32 | 0.165 | 0.36 | 0.29 | 0.23 | 0.37 | 0.280 | 0.140 | 0.310 | 0.280 | 0.165 | 0.320 |
185 | 0.25 | 0.27 | 0.26 | 0.37 | 0.26 | 0.165 | 0.30 | 0.23 | 0.23 | 0.32 | 0.220 | 0.140 | 0.260 | 0.220 | 0.165 | 0.280 |
240 | 0.19 | 0.21 | 0.26 | 0.33 | 0.20 | 0.160 | 0.25 | 0.185 | 0.22 | 0.29 | 0.170 | 0.140 | 0.220 | 0.170 | 0.165 | 0.240 |
300 | 0.155 | 0.175 | 0.25 | 0.31 | 0.16 | 0.160 | 0.22 | 0.150 | 0.22 | 0.27 | 0.140 | 0.140 | 0.195 | 0.135 | 0.160 | 0.210 |
400 | 0.12 | 0.140 | 0.25 | 0.29 | 0.13 | 0.155 | 0.20 | 0.125 | 0.22 | 0.25 | 0.110 | 0.135 | 0.175 | 0.110 | 0.160 | 0.195 |
500 | 0.093 | 0.120 | 0.25 | 0.28 | 0.105 | 0.155 | 0.185 | 0.100 | 0.22 | 0.24 | 0.090 | 0.135 | 0.160 | 0.088 | 0.160 | 0.180 |
630 | 0.072 | 0.100 | 0.25 | 0.27 | 0.086 | 0.155 | 0.175 | 0.088 | 0.21 | 0.23 | 0.074 | 0.135 | 0.150 | 0.071 | 0.160 | 0.170 |