RE-2Y(St)HSWAH 90°C / 300V
STANDARDS | Basic design to EN 50288-7 |
APPLICATION | Instrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations. |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance | ICEA S-73-532** |
Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min.60% of elongation.
VOLTAGE RATING | 300/500V |
CABLE CONSTRUCTION | |
Conductor: | Annealed copper solid or plain copper stranded to IEC 60228 Class 2. |
Insulation: | PE compound, EN 50290. 2-23. |
Pair: | Two insulated conductors uniformly twisted together with a lay not exceeding 100mm |
Binder tape: | PETP transparent tape |
Overall Screen: | Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² |
Inner Sheath: | LSZH compound |
Amouring: | Galvanized steel wire armour |
Outer Sheath: | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. |
COLOUR CODE | |
Insulation: | Black / White, continuously numbered on white core(1, 2..)for multipair. |
Outer Sheath: | Black or blue for intrinsically safe systems |
Physical AND THERMAL PROPERTIES | |
Temperature Range During Operation (Fixed State): | -30°C – +90°C |
Temperature Range During Installation (Mobile State): | -5°C – +50°C |
Minimum Bending Radius: | 10 X Overall Diameter |
Cable Code | RE-2Y(St)HSWAH | |||||||
No. of Pairsx2 xCross Section | Nominal Insulation Thick -ness | Nominal Inner Sheath Thick -ness | Nominal Overall Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thick -ness | Nominal Overall Diameter | Approx. Weight | |
No.x2xmm2 | mm2 | mm | mm | mm | mm | mm | kg/km | |
RE-2Y(St)HSWAH 1P0.5 | 1x2x0.50 | 0.35 | 0.8 | 5.2 | 0.9 | 1.3 | 9.6 | 177 |
RE-2Y(St)HSWAH 1P0.75 | 1x2x0.75 | 0.38 | 0.8 | 5.6 | 0.9 | 1.3 | 10.0 | 199 |
RE-2Y(St)HSWAH 1P1.0 | 1x2x1.0 | 0.40 | 0.9 | 6.3 | 0.9 | 1.3 | 10.7 | 219 |
RE-2Y(St)HSWAH 1P1.3 | 1x2x1.3 | 0.45 | 0.9 | 6.8 | 0.9 | 1.3 | 11.2 | 241 |
RE-2Y(St)HSWAH 1P1.5 | 1x2x1.5 | 0.45 | 0.9 | 7.1 | 0.9 | 1.3 | 11.5 | 255 |
Note : Other conductor sizes & core configurations are available upon request
Electrical PROPERTIES
Conductor Area Size | mm 2 | 0.5 | 0.75 | 1.0 | 1.3 | 1.5 | |
Insulation thickness (nominal) | mm | 0.35 | 0.38 | 0.4 | 0.45 | 0.45 | |
Conductor resistance (20°C) | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | |
Insulation resistance (20°C) | MΩ.km(Min.) | 5000 | |||||
Mutual Capacitance (1 kHz) | pF/m(Max.) | 115 | |||||
Capacitance unbalance(1 kHz) | pF/500 m (Max.) | 500 | |||||
Inductance | mH/km (Max.) | 1 | |||||
L / R (ratio) (max.) | μH/Ω | 25 | 25 | 25 | 40 | 40 | |
Operating voltage Urms | V | 300 | |||||
Test Voltage | Core to Core | V | 1500 | ||||
Core to Screen | V | 1500 |
RE-2Y(St)HSWAH 90°C / 300V
STANDARDS | Basic design to EN 50288-7 |
APPLICATION | Instrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations. |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance | ICEA S-73-532** |
Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min.60% of elongation.
VOLTAGE RATING | 300/500V |
CABLE CONSTRUCTION | |
Conductor: | Annealed copper solid or plain copper stranded to IEC 60228 Class 2. |
Insulation: | PE compound, EN 50290. 2-23. |
Pair: | Two insulated conductors uniformly twisted together with a lay not exceeding 100mm |
Binder tape: | PETP transparent tape |
Overall Screen: | Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² |
Inner Sheath: | LSZH compound |
Amouring: | Galvanized steel wire armour |
Outer Sheath: | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. |
COLOUR CODE | |
Insulation: | Black / White, continuously numbered on white core(1, 2..)for multipair. |
Outer Sheath: | Black or blue for intrinsically safe systems |
Physical AND THERMAL PROPERTIES | |
Temperature Range During Operation (Fixed State): | -30°C – +90°C |
Temperature Range During Installation (Mobile State): | -5°C – +50°C |
Minimum Bending Radius: | 10 X Overall Diameter |
Cable Code | RE-2Y(St)HSWAH | |||||||
No. of Pairsx2 xCross Section | Nominal Insulation Thick -ness | Nominal Inner Sheath Thick -ness | Nominal Overall Diameter Over Inner Sheath | Nominal Armour Wire Diameter | Nominal Outer Sheath Thick -ness | Nominal Overall Diameter | Approx. Weight | |
No.x2xmm2 | mm2 | mm | mm | mm | mm | mm | kg/km | |
RE-2Y(St)HSWAH 1P0.5 | 1x2x0.50 | 0.35 | 0.8 | 5.2 | 0.9 | 1.3 | 9.6 | 177 |
RE-2Y(St)HSWAH 1P0.75 | 1x2x0.75 | 0.38 | 0.8 | 5.6 | 0.9 | 1.3 | 10.0 | 199 |
RE-2Y(St)HSWAH 1P1.0 | 1x2x1.0 | 0.40 | 0.9 | 6.3 | 0.9 | 1.3 | 10.7 | 219 |
RE-2Y(St)HSWAH 1P1.3 | 1x2x1.3 | 0.45 | 0.9 | 6.8 | 0.9 | 1.3 | 11.2 | 241 |
RE-2Y(St)HSWAH 1P1.5 | 1x2x1.5 | 0.45 | 0.9 | 7.1 | 0.9 | 1.3 | 11.5 | 255 |
Note : Other conductor sizes & core configurations are available upon request
Electrical PROPERTIES
Conductor Area Size | mm 2 | 0.5 | 0.75 | 1.0 | 1.3 | 1.5 | |
Insulation thickness (nominal) | mm | 0.35 | 0.38 | 0.4 | 0.45 | 0.45 | |
Conductor resistance (20°C) | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | |
Insulation resistance (20°C) | MΩ.km(Min.) | 5000 | |||||
Mutual Capacitance (1 kHz) | pF/m(Max.) | 115 | |||||
Capacitance unbalance(1 kHz) | pF/500 m (Max.) | 500 | |||||
Inductance | mH/km (Max.) | 1 | |||||
L / R (ratio) (max.) | μH/Ω | 25 | 25 | 25 | 40 | 40 | |
Operating voltage Urms | V | 300 | |||||
Test Voltage | Core to Core | V | 1500 | ||||
Core to Screen | V | 1500 |