Availability: | |
---|---|
Quantity: | |
Applications : | These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas. |
Standards : | IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004 |
Conductors : | Circular stranded copper wire to IEC 60228 class 2. |
Insulation : | XLPE. |
Bedding : | Halogen free thermoplastic compound. |
Armour : | Tinned copper wire braid. |
Metal Screen : | Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor. |
Outer Sheath : | Halogen free thermoplastic compound, SHF1, coloured grey. |
Electrical Characteristics :
Nominal Cross Section Area | mm² | 2.5 |
Maximum Resistant@20℃ | Ω/km | 7.41 |
Continuous Current Rating@45℃2 Core | A | 26 |
Short Circuit Current 1s | A | 360 |
Operating Voltage | V | 250 |
Mechanical and Thermal Properties :
Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight :
Construction No. of elements×No. of cores in element×Cross section (mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | |
Inner | Outer | ||||
2×1×2.5 | 0.7 | 1.1 | 1.2 | 10.0 | 180 |
Applications : | These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas. |
Standards : | IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004 |
Conductors : | Circular stranded copper wire to IEC 60228 class 2. |
Insulation : | XLPE. |
Bedding : | Halogen free thermoplastic compound. |
Armour : | Tinned copper wire braid. |
Metal Screen : | Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor. |
Outer Sheath : | Halogen free thermoplastic compound, SHF1, coloured grey. |
Electrical Characteristics :
Nominal Cross Section Area | mm² | 2.5 |
Maximum Resistant@20℃ | Ω/km | 7.41 |
Continuous Current Rating@45℃2 Core | A | 26 |
Short Circuit Current 1s | A | 360 |
Operating Voltage | V | 250 |
Mechanical and Thermal Properties :
Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight :
Construction No. of elements×No. of cores in element×Cross section (mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | |
Inner | Outer | ||||
2×1×2.5 | 0.7 | 1.1 | 1.2 | 10.0 | 180 |