Availability: | |
---|---|
Quantity: | |
Application
These cables are suitable for indoor and outdoor applications, where a high safety against flame is required .
Public address and emergency voice communication system and traffic control centres.
Control and instrumentation service in industrial, commercial and residential buildings.
Such as: Schools&Universities, Hospital, Markets & Malls, Hotels, Theatres, Cinemas, Airports, Underground stations, Tunnels, Recreational places& Amusement parks, Indoor work places.
Construction | |||||||||||||||||||
1 | Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228. | ||||||||||||||||||
Flexible class 5 or tinned conductor could be offer upon request. | |||||||||||||||||||
2 | Fire Barrier: Mica tape (MGT). | ||||||||||||||||||
3 | Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1. | ||||||||||||||||||
Insulation Color Code: | |||||||||||||||||||
Number of Cores | Color Code to IEC 60502-1 | Color Code to BS 5467 | |||||||||||||||||
2 | Red & Black | Brown & Blue | |||||||||||||||||
3 | Red, Yellow and Blue | Brown, Black and Grey | |||||||||||||||||
4 | Red, Yellow, Blue and Black | Blue, Brown, Black and Grey | |||||||||||||||||
5 | Red, Yellow, Blue, Black and | Green / Yellow, Blue, Brown, | |||||||||||||||||
Green / Yellow | Black and Grey | ||||||||||||||||||
Assembly: Cores cabled together with PP filler and covered with non-woven tape. | |||||||||||||||||||
4 | Bedding: Low Smoke Zero Halogen (LSZH) Compound Type ST8 (90°C) of IEC 60502-1. | ||||||||||||||||||
Bedding Colour: Black. | |||||||||||||||||||
5 | Armour: Galvanized steel wire armoured (SWA). | ||||||||||||||||||
6 | Outer Sheath: Low smoke zero halogen (LSZH) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1. | ||||||||||||||||||
Outer Sheath Color: Orange or other color as per customer request. | |||||||||||||||||||
Electrical Characteristics | |||||||||||||||||||
Recommended rated voltages U0 | |||||||||||||||||||
Highest system voltage | Rated voltage (U0) (kV) | ||||||||||||||||||
(Um) (kV) | Categories A and B | Category C | |||||||||||||||||
1,2 | 0,6 | 0,6 | |||||||||||||||||
Routine test voltages | |||||||||||||||||||
Rated voltage U0 (kV) | 0,6 | ||||||||||||||||||
Test voltage (kV) | 3,5 | ||||||||||||||||||
Maximum conductor temperatures for different types of insulating compound | |||||||||||||||||||
Maximum conductor temperature (°C) | |||||||||||||||||||
Normal operation | Short-circuit (5 s maximum duration) | ||||||||||||||||||
90 | 250 |
Operating Temperature: -15°C to 90°C
Test Voltage: 3.5 kV for 5 minutes
Reference Standards
Design Specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387(C,W,Z), SS299(C,W,Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2
Application
These cables are suitable for indoor and outdoor applications, where a high safety against flame is required .
Public address and emergency voice communication system and traffic control centres.
Control and instrumentation service in industrial, commercial and residential buildings.
Such as: Schools&Universities, Hospital, Markets & Malls, Hotels, Theatres, Cinemas, Airports, Underground stations, Tunnels, Recreational places& Amusement parks, Indoor work places.
Construction | |||||||||||||||||||
1 | Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228. | ||||||||||||||||||
Flexible class 5 or tinned conductor could be offer upon request. | |||||||||||||||||||
2 | Fire Barrier: Mica tape (MGT). | ||||||||||||||||||
3 | Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1. | ||||||||||||||||||
Insulation Color Code: | |||||||||||||||||||
Number of Cores | Color Code to IEC 60502-1 | Color Code to BS 5467 | |||||||||||||||||
2 | Red & Black | Brown & Blue | |||||||||||||||||
3 | Red, Yellow and Blue | Brown, Black and Grey | |||||||||||||||||
4 | Red, Yellow, Blue and Black | Blue, Brown, Black and Grey | |||||||||||||||||
5 | Red, Yellow, Blue, Black and | Green / Yellow, Blue, Brown, | |||||||||||||||||
Green / Yellow | Black and Grey | ||||||||||||||||||
Assembly: Cores cabled together with PP filler and covered with non-woven tape. | |||||||||||||||||||
4 | Bedding: Low Smoke Zero Halogen (LSZH) Compound Type ST8 (90°C) of IEC 60502-1. | ||||||||||||||||||
Bedding Colour: Black. | |||||||||||||||||||
5 | Armour: Galvanized steel wire armoured (SWA). | ||||||||||||||||||
6 | Outer Sheath: Low smoke zero halogen (LSZH) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1. | ||||||||||||||||||
Outer Sheath Color: Orange or other color as per customer request. | |||||||||||||||||||
Electrical Characteristics | |||||||||||||||||||
Recommended rated voltages U0 | |||||||||||||||||||
Highest system voltage | Rated voltage (U0) (kV) | ||||||||||||||||||
(Um) (kV) | Categories A and B | Category C | |||||||||||||||||
1,2 | 0,6 | 0,6 | |||||||||||||||||
Routine test voltages | |||||||||||||||||||
Rated voltage U0 (kV) | 0,6 | ||||||||||||||||||
Test voltage (kV) | 3,5 | ||||||||||||||||||
Maximum conductor temperatures for different types of insulating compound | |||||||||||||||||||
Maximum conductor temperature (°C) | |||||||||||||||||||
Normal operation | Short-circuit (5 s maximum duration) | ||||||||||||||||||
90 | 250 |
Operating Temperature: -15°C to 90°C
Test Voltage: 3.5 kV for 5 minutes
Reference Standards
Design Specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Fire Resistance: BS6387(C,W,Z), SS299(C,W,Z), IEC60331
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2