LSZH SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V LSZH Sheathed, Screened (3C+3E)
Application: | The cables are designed specifically to suit the broad spectrum of requirements of Variable Speed Drives and also include features for reducing the transmission of electromagnetic interference. |
Standard: | Basic design to IEC 60502-1 |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Extruded cross-linked XLPE compound.
Screen: Copper Tape
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
COLOUR CODE
Insulation Colour: Red, Yellow, Blue, Green/Yellow (x3)
Outer sheath: Black or as order
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C for XLPE
250°C in short-circuit for 5s max.
Minimum bending radius: 10 x Overall Diameter
CONSTRUCTION PARAMETERS
Conductor | ||||||
No. of Core X Cross Section | No./Nominal Diameter of Strands | Combined Earth Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
mm² | No./mm | mm² | mm | mm | mm | kg/km |
3x1.5 | 7/0.53 | 4.5(3x1.5) | 0.7 | 1.8 | 13.6 | 325 |
3x2.5 | 7/0.67 | 4.5(3x1.5) | 0.7 | 1.8 | 14.8 | 380 |
3x4 | 7/0.85 | 4.5(3x1.5) | 0.7 | 1.8 | 15.8 | 440 |
3x6 | 7/1.04 | 7.5(3x2.5) | 0.7 | 1.8 | 16.9 | 550 |
3x10 | 7/1.35 | 12(3x4) | 0.7 | 1.8 | 18.6 | 750 |
3x16 | 7/1.70 | 18(3x6) | 0.7 | 1.8 | 20.8 | 1000 |
3x25 | 7/2.14 | 30(3x10) | 0.9 | 1.8 | 24.0 | 1470 |
3x35 | 7/2.52 | 30(3x10) | 0.9 | 1.8 | 25.6 | 1890 |
3x50 | 19/1.78 | 30(3x10) | 1.0 | 1.9 | 31.1 | 2300 |
3x70 | 19/2.14 | 48(3x16) | 1.1 | 2.0 | 34.6 | 3200 |
3x95 | 19/2.52 | 48(3x16) | 1.1 | 2.2 | 39.3 | 4200 |
3x120 | 37/2.03 | 75(3x25) | 1.2 | 2.3 | 44.0 | 5400 |
3x150 | 37/2.25 | 75(3x25) | 1.4 | 2.5 | 49.0 | 6400 |
3x185 | 37/2.52 | 105(3x35) | 1.6 | 2.6 | 54.0 | 7900 |
3x240 | 61/2.25 | 150(3x50) | 1.7 | 2.8 | 61.0 | 10200 |
3x300 | 61/2.52 | 150(3x50) | 1.8 | 3.0 | 67.0 | 12300 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor cross- sectional area | Reference method 4 (enclosed in conduit in thermally insulating wall etc) | Reference method 3 (enclosed in conduit on a wall or in trunking etc) | Reference method 1 (clipped direct) | Reference method 11 (on a perforated cable tray, horizontal or vertical) | Reference method 12 (free air) | ||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | |||||||||
2 cables, single- phase a.c. or d.c. | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c. flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or 3 c ables three phase | 2 cables, single- phase a.c. or d.c. or 3 cables three phase | 3 cables, trefoil 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm² | A | A | A | A | A | A | A | A | A | A | A |
1.5 | 18 | 17 | 22 | 19 | 25 | 23 | - | - | - | - | - |
2.5 | 24 | 23 | 30 | 26 | 34 | 31 | - | - | - | - | - |
4 | 33 | 30 | 40 | 35 | 46 | 41 | - | - | - | - | - |
6 | 43 | 39 | 51 | 45 | 59 | 54 | - | - | - | - | - |
10 | 58 | 53 | 71 | 63 | 81 | 74 | - | - | - | - | - |
16 | 76 | 70 | 95 | 85 | 109 | 99 | - | - | - | - | - |
25 | 100 | 91 | 126 | 111 | 143 | 130 | 158 | 140 | 183 | 163 | 138 |
35 | 125 | 111 | 156 | 138 | 176 | 161 | 195 | 176 | 226 | 203 | 171 |
50 | 149 | 135 | 189 | 168 | 228 | 209 | 293 | 215 | 274 | 246 | 209 |
70 | 189 | 170 | 240 | 214 | 293 | 268 | 308 | 279 | 351 | 318 | 270 |
95 | 228 | 205 | 290 | 259 | 355 | 326 | 375 | 341 | 426 | 389 | 330 |
120 | 263 | 235 | 336 | 299 | 413 | 379 | 436 | 398 | 495 | 453 | 385 |
150 | 300 | 270 | 375 | 328 | 476 | 436 | 505 | 461 | 570 | 524 | 445 |
185 | 341 | 306 | 426 | 370 | 545 | 500 | 579 | 530 | 651 | 600 | 511 |
240 | 400 | 358 | 500 | 433 | 644 | 590 | 686 | 630 | 769 | 711 | 606 |
300 | 459 | 410 | 573 | 493 | 743 | 681 | 794 | 730 | 886 | 824 | 701 |
Voltage Drop (Per Amp Per Meter)
Size of conductor | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | |||||||||||||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1 and 11 (clipped direct or on trays touching) | Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1, 11 and 12 (in trefoil) | Ref. Methods 1 and 11(Flat and touching) | ||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | ||||||||||
mm² | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||||||||
1.5 | 31 | 31 | 27 | 27 | 27 | 27 | ||||||||||
2.5 | 19 | 19 | 16 | 16 | 16 | 16 | ||||||||||
4 | 33 | 12 | 10 | 10 | 10 | 10 | ||||||||||
6 | 7.8 | 7.9 | 6.8 | 6.8 | 6.8 | 6.8 | ||||||||||
10 | 4.7 | 4.7 | 4.7 | 4 | 4 | 4 | ||||||||||
16 | 2.9 | 2.9 | 2.9 | 2.5 | 2.5 | 2.5 | ||||||||||
r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
25 | 1.85 | 1.85 | 0.31 | 1.90 | 1.85 | 0.190 | 1.85 | 1.60 | 0.27 | 1.65 | 1.600 | 0.165 | 1.600 | 1.600 | 0.190 | 1.600 |
35 | 1.35 | 1.35 | 0.29 | 1.35 | 1.35 | 0.180 | 1.35 | 1.15 | 0.25 | 1.15 | 1.150 | 0.155 | 1.50 | 1.150 | 0.180 | 1.150 |
50 | 0.99 | 1.00 | 0.29 | 1.05 | 0.99 | 0.180 | 1.00 | 0.87 | 0.25 | 0.90 | 0.860 | 0.155 | 0.870 | 0.860 | 0.180 | 0.870 |
70 | 0.68 | 0.70 | 0.28 | 0.75 | 0.68 | 0.175 | 0.71 | 0.60 | 0.24 | 0.65 | 0.590 | 0.150 | 0.610 | 0.590 | 0.175 | 0.620 |
95 | 0.49 | 0.51 | 0.27 | 0.58 | 0.49 | 0.170 | 0.52 | 0.44 | 0.23 | 0.50 | 0.430 | 0.145 | 0.450 | 0.430 | 0.170 | 0.460 |
120 | 0.39 | 0.41 | 0.26 | 0.48 | 0.39 | 0.165 | 0.43 | 0.35 | 0.23 | 0.42 | 0.340 | 0.140 | 0.370 | 0.340 | 0.165 | 0.380 |
150 | 0.32 | 0.33 | 0.26 | 0.43 | 0.32 | 0.165 | 0.36 | 0.29 | 0.23 | 0.37 | 0.280 | 0.140 | 0.310 | 0.280 | 0.165 | 0.320 |
185 | 0.25 | 0.27 | 0.26 | 0.37 | 0.26 | 0.165 | 0.30 | 0.23 | 0.23 | 0.32 | 0.220 | 0.140 | 0.260 | 0.220 | 0.165 | 0.280 |
240 | 0.19 | 0.21 | 0.26 | 0.33 | 0.20 | 0.160 | 0.25 | 0.185 | 0.22 | 0.29 | 0.170 | 0.140 | 0.220 | 0.170 | 0.165 | 0.240 |
300 | 0.155 | 0.175 | 0.25 | 0.31 | 0.16 | 0.160 | 0.22 | 0.150 | 0.22 | 0.27 | 0.140 | 0.140 | 0.195 | 0.135 | 0.160 | 0.210 |
LSZH SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V LSZH Sheathed, Screened (3C+3E)
Application: | The cables are designed specifically to suit the broad spectrum of requirements of Variable Speed Drives and also include features for reducing the transmission of electromagnetic interference. |
Standard: | Basic design to IEC 60502-1 |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
600/1000V
CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Extruded cross-linked XLPE compound.
Screen: Copper Tape
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
COLOUR CODE
Insulation Colour: Red, Yellow, Blue, Green/Yellow (x3)
Outer sheath: Black or as order
Physical AND THERMAL PROPERTIES
Temperature range during operation: Max.90°C for XLPE
250°C in short-circuit for 5s max.
Minimum bending radius: 10 x Overall Diameter
CONSTRUCTION PARAMETERS
Conductor | ||||||
No. of Core X Cross Section | No./Nominal Diameter of Strands | Combined Earth Size | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
mm² | No./mm | mm² | mm | mm | mm | kg/km |
3x1.5 | 7/0.53 | 4.5(3x1.5) | 0.7 | 1.8 | 13.6 | 325 |
3x2.5 | 7/0.67 | 4.5(3x1.5) | 0.7 | 1.8 | 14.8 | 380 |
3x4 | 7/0.85 | 4.5(3x1.5) | 0.7 | 1.8 | 15.8 | 440 |
3x6 | 7/1.04 | 7.5(3x2.5) | 0.7 | 1.8 | 16.9 | 550 |
3x10 | 7/1.35 | 12(3x4) | 0.7 | 1.8 | 18.6 | 750 |
3x16 | 7/1.70 | 18(3x6) | 0.7 | 1.8 | 20.8 | 1000 |
3x25 | 7/2.14 | 30(3x10) | 0.9 | 1.8 | 24.0 | 1470 |
3x35 | 7/2.52 | 30(3x10) | 0.9 | 1.8 | 25.6 | 1890 |
3x50 | 19/1.78 | 30(3x10) | 1.0 | 1.9 | 31.1 | 2300 |
3x70 | 19/2.14 | 48(3x16) | 1.1 | 2.0 | 34.6 | 3200 |
3x95 | 19/2.52 | 48(3x16) | 1.1 | 2.2 | 39.3 | 4200 |
3x120 | 37/2.03 | 75(3x25) | 1.2 | 2.3 | 44.0 | 5400 |
3x150 | 37/2.25 | 75(3x25) | 1.4 | 2.5 | 49.0 | 6400 |
3x185 | 37/2.52 | 105(3x35) | 1.6 | 2.6 | 54.0 | 7900 |
3x240 | 61/2.25 | 150(3x50) | 1.7 | 2.8 | 61.0 | 10200 |
3x300 | 61/2.52 | 150(3x50) | 1.8 | 3.0 | 67.0 | 12300 |
Electrical PROPERTIES
Conductor Operating Temperature : 90°C
Ambient Temperature : 30°C
Current-Carrying Capacities (Amp)
Conductor cross- sectional area | Reference method 4 (enclosed in conduit in thermally insulating wall etc) | Reference method 3 (enclosed in conduit on a wall or in trunking etc) | Reference method 1 (clipped direct) | Reference method 11 (on a perforated cable tray, horizontal or vertical) | Reference method 12 (free air) | ||||||
Horizontal flat spaced | Vertical flat spaced | Trefoil | |||||||||
2 cables, single- phase a.c. or d.c. | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c | 3 or 4 cables, 3-phase a.c. | 2 cables, single- phase a.c. or d.c. flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or flat and touching | 3 or 4 cables, 3-phase a.c. flat and touching or trefoil | 2 cables, single- phase a.c. or d.c. or 3 c ables three phase | 2 cables, single- phase a.c. or d.c. or 3 cables three phase | 3 cables, trefoil 3-phase a.c. | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
mm² | A | A | A | A | A | A | A | A | A | A | A |
1.5 | 18 | 17 | 22 | 19 | 25 | 23 | - | - | - | - | - |
2.5 | 24 | 23 | 30 | 26 | 34 | 31 | - | - | - | - | - |
4 | 33 | 30 | 40 | 35 | 46 | 41 | - | - | - | - | - |
6 | 43 | 39 | 51 | 45 | 59 | 54 | - | - | - | - | - |
10 | 58 | 53 | 71 | 63 | 81 | 74 | - | - | - | - | - |
16 | 76 | 70 | 95 | 85 | 109 | 99 | - | - | - | - | - |
25 | 100 | 91 | 126 | 111 | 143 | 130 | 158 | 140 | 183 | 163 | 138 |
35 | 125 | 111 | 156 | 138 | 176 | 161 | 195 | 176 | 226 | 203 | 171 |
50 | 149 | 135 | 189 | 168 | 228 | 209 | 293 | 215 | 274 | 246 | 209 |
70 | 189 | 170 | 240 | 214 | 293 | 268 | 308 | 279 | 351 | 318 | 270 |
95 | 228 | 205 | 290 | 259 | 355 | 326 | 375 | 341 | 426 | 389 | 330 |
120 | 263 | 235 | 336 | 299 | 413 | 379 | 436 | 398 | 495 | 453 | 385 |
150 | 300 | 270 | 375 | 328 | 476 | 436 | 505 | 461 | 570 | 524 | 445 |
185 | 341 | 306 | 426 | 370 | 545 | 500 | 579 | 530 | 651 | 600 | 511 |
240 | 400 | 358 | 500 | 433 | 644 | 590 | 686 | 630 | 769 | 711 | 606 |
300 | 459 | 410 | 573 | 493 | 743 | 681 | 794 | 730 | 886 | 824 | 701 |
Voltage Drop (Per Amp Per Meter)
Size of conductor | 2 cables d.c. | 2 cables, single-phase a.c. | 3 or 4 cables, 3-phase a.c. | |||||||||||||
Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1 and 11 (clipped direct or on trays touching) | Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall) | Ref. Methods 1, 11 and 12 (in trefoil) | Ref. Methods 1 and 11(Flat and touching) | ||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | ||||||||||
mm² | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | ||||||||||
1.5 | 31 | 31 | 27 | 27 | 27 | 27 | ||||||||||
2.5 | 19 | 19 | 16 | 16 | 16 | 16 | ||||||||||
4 | 33 | 12 | 10 | 10 | 10 | 10 | ||||||||||
6 | 7.8 | 7.9 | 6.8 | 6.8 | 6.8 | 6.8 | ||||||||||
10 | 4.7 | 4.7 | 4.7 | 4 | 4 | 4 | ||||||||||
16 | 2.9 | 2.9 | 2.9 | 2.5 | 2.5 | 2.5 | ||||||||||
r | x | z | r | x | z | r | x | z | r | x | z | r | x | z | ||
25 | 1.85 | 1.85 | 0.31 | 1.90 | 1.85 | 0.190 | 1.85 | 1.60 | 0.27 | 1.65 | 1.600 | 0.165 | 1.600 | 1.600 | 0.190 | 1.600 |
35 | 1.35 | 1.35 | 0.29 | 1.35 | 1.35 | 0.180 | 1.35 | 1.15 | 0.25 | 1.15 | 1.150 | 0.155 | 1.50 | 1.150 | 0.180 | 1.150 |
50 | 0.99 | 1.00 | 0.29 | 1.05 | 0.99 | 0.180 | 1.00 | 0.87 | 0.25 | 0.90 | 0.860 | 0.155 | 0.870 | 0.860 | 0.180 | 0.870 |
70 | 0.68 | 0.70 | 0.28 | 0.75 | 0.68 | 0.175 | 0.71 | 0.60 | 0.24 | 0.65 | 0.590 | 0.150 | 0.610 | 0.590 | 0.175 | 0.620 |
95 | 0.49 | 0.51 | 0.27 | 0.58 | 0.49 | 0.170 | 0.52 | 0.44 | 0.23 | 0.50 | 0.430 | 0.145 | 0.450 | 0.430 | 0.170 | 0.460 |
120 | 0.39 | 0.41 | 0.26 | 0.48 | 0.39 | 0.165 | 0.43 | 0.35 | 0.23 | 0.42 | 0.340 | 0.140 | 0.370 | 0.340 | 0.165 | 0.380 |
150 | 0.32 | 0.33 | 0.26 | 0.43 | 0.32 | 0.165 | 0.36 | 0.29 | 0.23 | 0.37 | 0.280 | 0.140 | 0.310 | 0.280 | 0.165 | 0.320 |
185 | 0.25 | 0.27 | 0.26 | 0.37 | 0.26 | 0.165 | 0.30 | 0.23 | 0.23 | 0.32 | 0.220 | 0.140 | 0.260 | 0.220 | 0.165 | 0.280 |
240 | 0.19 | 0.21 | 0.26 | 0.33 | 0.20 | 0.160 | 0.25 | 0.185 | 0.22 | 0.29 | 0.170 | 0.140 | 0.220 | 0.170 | 0.165 | 0.240 |
300 | 0.155 | 0.175 | 0.25 | 0.31 | 0.16 | 0.160 | 0.22 | 0.150 | 0.22 | 0.27 | 0.140 | 0.140 | 0.195 | 0.135 | 0.160 | 0.210 |