Availability: | |
---|---|
Quantity: | |
FLRYY (FLRYY = FLRYWYW = FLRYWY = FLRYYW)
Application:
Special-purpose PVC cables for low voltage electrical installations in vehicles
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC
Sheath: PVC
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLYZ
Application:
These two core figure 8 speaker cable are ideal for auto loudspeaker connection.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC insulation Class B to ISO 6722 (lead free). Core identification:
-black-black/white, black-black/ red, black-black/blue or transparent with coloured trace.
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLRYYF
Application:
Two core flat PVC cable with thin wall automotive wire, ideal for use in automotive applications and help to reduce weight and volume in complex wiring harnesses.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC insulation Class B to ISO 6722 (lead free)
Core identification: 2 core - red, black or white, black
Sheath: Black, white, red or green PVC sheath
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLR4Y-A FLR4Y-B
Application:
Connecting cable for cable harnesses. High resistance to fuels and abrasion.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor
construction according to ISO 6722.
Insulation: Polyamide (PA)
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
Excellent fuel resistance.
FLR5Y
Application:
Single core cable with very good properties, e.g. for the connection of oxygen sensors or NOx-sensors.
Standars/Specification:
DIN 53505 ISO6722
Construction:
Conductor: Silver or Nickel plated copper
Insulation: PTFE
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +260 °C (3000 h)
Excellent fuel resistance.
FLR7Y-A FLR7Y-B
Application:
Connecting cable for cable harnesses. High resistance to fuels and abrasion.
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: ETFE
FLR12Y-A FLR12Y-B
Application:
Connecting wire for cable harnesses
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor
construction according to ISO 6722.
Insulation: TPE-E
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +150 °C (3000 h)
FLR13Y-A FLR13Y-B
Application:
Connecting wire for cable harnesses
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: TPE-E
Product Features:
Voltage rating: 60V
Temperature range: –40 °C to +150 °C (3000 h)
FLRYY (FLRYY = FLRYWYW = FLRYWY = FLRYYW)
Application:
Special-purpose PVC cables for low voltage electrical installations in vehicles
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC
Sheath: PVC
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLYZ
Application:
These two core figure 8 speaker cable are ideal for auto loudspeaker connection.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC insulation Class B to ISO 6722 (lead free). Core identification:
-black-black/white, black-black/ red, black-black/blue or transparent with coloured trace.
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLRYYF
Application:
Two core flat PVC cable with thin wall automotive wire, ideal for use in automotive applications and help to reduce weight and volume in complex wiring harnesses.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: PVC insulation Class B to ISO 6722 (lead free)
Core identification: 2 core - red, black or white, black
Sheath: Black, white, red or green PVC sheath
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
UV-resistant
Resistant to most oils, weather and chemicals
FLR4Y-A FLR4Y-B
Application:
Connecting cable for cable harnesses. High resistance to fuels and abrasion.
Standars/Specification:
ISO 6722, DIN 72551-6
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor
construction according to ISO 6722.
Insulation: Polyamide (PA)
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +105 °C (3000 h)
Excellent fuel resistance.
FLR5Y
Application:
Single core cable with very good properties, e.g. for the connection of oxygen sensors or NOx-sensors.
Standars/Specification:
DIN 53505 ISO6722
Construction:
Conductor: Silver or Nickel plated copper
Insulation: PTFE
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +260 °C (3000 h)
Excellent fuel resistance.
FLR7Y-A FLR7Y-B
Application:
Connecting cable for cable harnesses. High resistance to fuels and abrasion.
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: ETFE
FLR12Y-A FLR12Y-B
Application:
Connecting wire for cable harnesses
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor
construction according to ISO 6722.
Insulation: TPE-E
Product Features:
Voltage rating: 60 V d.c, 25 V a.c.
Temperature range: –40 °C to +150 °C (3000 h)
FLR13Y-A FLR13Y-B
Application:
Connecting wire for cable harnesses
Standars/Specification:
ISO6722
Construction:
Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or tinned. Conductor construction according to ISO 6722.
Insulation: TPE-E
Product Features:
Voltage rating: 60V
Temperature range: –40 °C to +150 °C (3000 h)