Construction
Inner conductor | Tinned copper | 19 x 0.18 mm | |
Dielectric | Low density PE | Φ2.95 ± 0.10 mm | |
Outer conductor(shield ) | Tinned copper | 140 x 0.10 mm | |
Shield coverage | 93% | ||
Sheath | PVC or LSZH | Φ5.00 ± 0.10 mm |
Electrical & Mechanical Characteristics
Impedance | 50±3 Ohm |
Nominal capacitance | 100 pF/m |
Velocity of propagation | 66% |
Insulation resistance | >2000 Mohm.Km |
Inner conductor resistance | 37.5 Ohm/Km |
Outer conductor resistance | 17 Ohm/Km |
Operating temperature range | -30 °C - +70 °C |
Copper Weight | 14.9 Kg/Km |
Cable weight (approx.) | 37.1 Kg/Km |
Screening effectiveness | >55 dB |
Attenuation
Frequency (MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) |
50 | 9.7 | 2.96 |
100 | 13.9 | 4.24 |
200 | 20.4 | 6.22 |
400 | 30 | 9.15 |
500 | 34.2 | 10.43 |
600 | 34.9 | 11.55 |
860 | 46.9 | 14.3 |
1000 | 51.8 | 15.79 |
Return Loss
30-300 MHz | >27dB |
300-600 MHz | >23dB |
600-900 MHz | >22dB |
Construction
Inner conductor | Tinned copper | 19 x 0.18 mm | |
Dielectric | Low density PE | Φ2.95 ± 0.10 mm | |
Outer conductor(shield ) | Tinned copper | 140 x 0.10 mm | |
Shield coverage | 93% | ||
Sheath | PVC or LSZH | Φ5.00 ± 0.10 mm |
Electrical & Mechanical Characteristics
Impedance | 50±3 Ohm |
Nominal capacitance | 100 pF/m |
Velocity of propagation | 66% |
Insulation resistance | >2000 Mohm.Km |
Inner conductor resistance | 37.5 Ohm/Km |
Outer conductor resistance | 17 Ohm/Km |
Operating temperature range | -30 °C - +70 °C |
Copper Weight | 14.9 Kg/Km |
Cable weight (approx.) | 37.1 Kg/Km |
Screening effectiveness | >55 dB |
Attenuation
Frequency (MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) |
50 | 9.7 | 2.96 |
100 | 13.9 | 4.24 |
200 | 20.4 | 6.22 |
400 | 30 | 9.15 |
500 | 34.2 | 10.43 |
600 | 34.9 | 11.55 |
860 | 46.9 | 14.3 |
1000 | 51.8 | 15.79 |
Return Loss
30-300 MHz | >27dB |
300-600 MHz | >23dB |
600-900 MHz | >22dB |