Availability: | |
---|---|
Quantity: | |
Application | These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free. |
Standards | IEC 60092-350/351/353/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be offered upon request. |
Insulation | XLPE |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). SHF2 can be offered upon request. |
Core Identification | Single core: Black. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +80℃ |
Dimensions and Weight
Single Core Armoured 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change –R to –F)
Part No. | Construction No. of cores×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
1C1.5 | 1×1.5 | 0.7 | 1.1 | 6.3 | 70 |
1C2.5 | 1×2.5 | 0.7 | 1.1 | 6.7 | 80 |
1C4 | 1×4 | 0.9 | 1.1 | 7.4 | 100 |
1C6 | 1×6 | 0.9 | 1.1 | 8.0 | 120 |
1C10 | 1×10 | 0.9 | 1.1 | 8.8 | 180 |
1C16 | 1×16 | 0.9 | 1.1 | 10.2 | 245 |
1C25 | 1×25 | 0.9 | 1.2 | 11.7 | 355 |
1C35 | 1×35 | 0.9 | 1.2 | 13.0 | 455 |
1C50 | 1×50 | 1.0 | 1.3 | 15.0 | 620 |
1C70 | 1×70 | 1.1 | 1.4 | 17.2 | 850 |
1C95 | 1×95 | 1.1 | 1.4 | 19.1 | 1115 |
1C120 | 1×120 | 1.2 | 1.5 | 21.1 | 1385 |
1C150 | 1×150 | 1.4 | 1.6 | 23.2 | 1690 |
1C185 | 1×185 | 1.6 | 1.6 | 25.5 | 2065 |
1C240 | 1×240 | 1.7 | 1.7 | 28.4 | 2640 |
1C300 | 1×300 | 1.8 | 1.8 | 31.3 | 3260 |
Application | These armoured cables are used on board of ships in all locations for fixed installations where cable protection is required. These cables are flame retardant, low smoke & halogen free. |
Standards | IEC 60092-350/351/353/359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1/2 IEC 61034 |
Construction | |
Conductors | Class 2 stranded copper conductor, round or sector shaped. Class 5 stranded conductors can be offered upon request. |
Insulation | XLPE |
Armour | Copper wire braid. |
Outer Sheath | LSOH (SHF1). SHF2 can be offered upon request. |
Core Identification | Single core: Black. |
Mechanical and Thermal Properties | Bending Radius for Fixed Installations: 6×OD Temperature Range: -30℃ ~ +80℃ |
Dimensions and Weight
Single Core Armoured 0.6/1kV (-R stands for class 2 conductor. For class 5 conductor, please change –R to –F)
Part No. | Construction No. of cores×Cross section(mm²) | Nominal Insulation Thickness mm | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
1C1.5 | 1×1.5 | 0.7 | 1.1 | 6.3 | 70 |
1C2.5 | 1×2.5 | 0.7 | 1.1 | 6.7 | 80 |
1C4 | 1×4 | 0.9 | 1.1 | 7.4 | 100 |
1C6 | 1×6 | 0.9 | 1.1 | 8.0 | 120 |
1C10 | 1×10 | 0.9 | 1.1 | 8.8 | 180 |
1C16 | 1×16 | 0.9 | 1.1 | 10.2 | 245 |
1C25 | 1×25 | 0.9 | 1.2 | 11.7 | 355 |
1C35 | 1×35 | 0.9 | 1.2 | 13.0 | 455 |
1C50 | 1×50 | 1.0 | 1.3 | 15.0 | 620 |
1C70 | 1×70 | 1.1 | 1.4 | 17.2 | 850 |
1C95 | 1×95 | 1.1 | 1.4 | 19.1 | 1115 |
1C120 | 1×120 | 1.2 | 1.5 | 21.1 | 1385 |
1C150 | 1×150 | 1.4 | 1.6 | 23.2 | 1690 |
1C185 | 1×185 | 1.6 | 1.6 | 25.5 | 2065 |
1C240 | 1×240 | 1.7 | 1.7 | 28.4 | 2640 |
1C300 | 1×300 | 1.8 | 1.8 | 31.3 | 3260 |